FUNCTIONS
LEISURE BATTERY CHARGE (B2)
a)
Through engine alternator: through separate relays when engine is on. The ignition electronically
controls the relays: parallel, fridge, awning light, etc.
b)
Trough 240V mains power through battery charger.
c)
Trough solar panel: through solar charge regulator.
MINIMUM VOLTAGE CONTROL (BATTERY PROTECTION)
The electronic battery protection device cuts off the 12V fuses when leisure battery reaches 10V and
disables: pump, lights, Multimadia and stove.
Symbol ref. 1 is the visual alarm signal.
It is possible to reactivate all fuses for one minute by pressing the on/off button (ref. 06 on control
panel).
The control panel automatically turns off with a voltage lower than 9.5V.
Fuses are automatically reactivated when voltage is greater than 13.5V.
This device doesn't control the functions: fridge, step and the auxiliary exit DIR.
ELECTRONIC BATTERY SEPARATOR
An electronic device controlled by the ignition switches on the batteries parallel when the chassis
battery voltage is over 13.5V and switches off when engine is off or voltage is lower than 12.2V. This
device operates only if the B2 leisure battery is connected.
This device controls the relays of the fuses depending from exit simulating +OUT D+ (3 way function
fridge, awning light, antenna motion, etc.).
DIGITAL CLOCK
To set clock see "SETTING".
AMPERE METER
The amperemeter is inside the DS520-AN module.
- It measures the current of the leisure battery, users' consumption and recharge through battery
charger, engine alternator and solar panels.
- Measurement range is: -40A ÷ +40A.
- Measurement is carried out as difference between charging and discharging currents: a positive value
indicates a charging current, a negative value indicates a discharging current.
To measure the charging of a sole source (battery charger, alternator or solar panels), turn off all
items and other charging sources.
To measure the consumption of a sole user, disconnect all charging sources and turn off all unused
items.
BROKEN FUSE ALARM
Under each fuse is positioned a red LED.
The lighting of the LED signals that the fuse is broken and it is necessary to replace it with another fuse
with the same value. The alarm is activated only when the control panel is on and the user related to
the fuse is switched on.
NOTE: before replacing the fuse find out the problem that determined the intervention of the protection
(blown fuse) and fix it, it may be necessary to have a qualified technician assist.