the air tank (big one) and the output pressure (small one).
Air Intake Filter (5):
This filter is designed to clean air coming into the pump. This filter must
always be clean and ventilation openings free from obstructions. See "Maintenance".
Air Compressor Pump (6):
To compress air, the pistons moves up and down in the cylinder. On
the down stroke, air is drawn in through the air intake valves. The exhaust valve remains closed. On
the upstroke of the piston, air is compressed. The intake valves close and compressed air is forced
out through the exhaust valve, through the outlet tube, through the check valve and into the air tank.
Working air is not available until the compressor has raised the air tank pressure above that required
at the air outlet.
Air Pressure Regulator (7):
Controls the air pressure shown on the outlet pressure gauge.
Pull the knob out and turn clockwise to increase pressure and counterclockwise to decrease pressure.
When the desired pressure is reached push knob in to lock in place.
Quick Connect (8):
Connect the air hose or accessory easily.
Check Valve (not shown):
When the air compressor is operating, the check valve is "open",
allowing compressed air to enter the air tank. When the air compressor reaches "cut-out" pressure,
the check valve "closes", allowing air pressure to remain inside the air tank.
Drain Valve (not shown):
Located at the base of the air tank to drain condensation.

INSTALLATION

WARNING: Improper electrical installation of this product may void its warranty and your fire
insurance. Have circuit wiring performed by qualified personnel such as a licensed
electricians who is familiar with the current national electrical code and any prevailing local
electrical codes.
Location of the Air Compressor
WARNING: The manifold assembly does not provide adequate stability or support for lifting
the unit. If the unit must be moved, use the air tank for lifting.
Operate the air compressor in a clean, dry, and well-ventilated area. The air intake filter must be kept
clear of obstructions which could reduce air delivery of the air compressor. The air compressor should
be located at least 12" away from walls or other obstructions that could interfere with the flow of air.
For Belt Driven model,
The air compressor crankcase and head are designed with fins to provide proper cooling.
The flywheel side of the unit should be placed toward the wall and protected with a totally enclosed
belt guard. The area should allow space on all sides for air circulation and for ease of normal
maintenance.
Keep the unit away from areas, which have dirt, vapor, and combustible fumes in the atmosphere
which may clog and gum the intake filter and valves, causing inefficient operation. If humidity is high,
an air filter can be installed in line to remove excessive moisture.
5