Failure to properly configure the GPIO Port can result in damage to the printer and / or connected devices.
WARNING
Pin
Signal Name / Direction
1
+5 VDC
2
Input 6
3
Input 3
4
Output 6
5
Output 3
6
Ground
7
Input 5
8
Input 2
9
Output 5
10
Output 2
11
+24 VDC
12
Input 4
13
Input 1
14
Output 4
15
Output 1
[1]
Signal directions given relative to the printer.
[1]
Jumper
Position
Installed
JMP 11
Removed
N/A
N/A
N/A
N/A
Installed: Pins 1 – 2
JMP 7
Installed: Pins 2 – 3
Removed
Installed: Pins 1 – 2
JMP 4
Installed: Pins 2 – 3
Removed
Installed
JMP 10
Removed
N/A
N/A
N/A
N/A
Installed: Pins 1 – 2
JMP 6
Installed: Pins 2 – 3
Removed
Installed: Pins 1 – 2
JMP 3
Installed: Pins 2 – 3
Removed
N/A
N/A
N/A
N/A
N/A
N/A
Installed: Pins 1 – 2
JMP 5
Installed: Pins 2 – 3
Removed
Installed: Pins 1 – 2
JMP 2
Installed: Pins 2 – 3
Removed
GPI/O Port B Overview
Printer +5VDC is used (.5 amp maximum).
Note:
Drawing more than .5 amps can cause unreliable printer operation.
+5VDC must be supplied.
Programmed input function.
Programmed input function.
Programmed output function pulled-up to +5VDC.
Programmed output function pulled-up to +24VDC.
An external voltage via external pull-ups will determine this level, not exceed +30VDC.
Programmed output function pulled-up to +5VDC.
Programmed output function pulled-up to +24VDC.
An external voltage via external pull-ups will determine this level, not exceed +30VDC.
Printer chassis is used.
Ground must be supplied.
Programmed input function.
Programmed input function.
Programmed output function pulled-up to +5VDC.
Programmed output function pulled-up to +24VDC.
An external voltage via external pull-ups will determine this level, not exceed +30VDC.
Programmed output function pulled-up to +5VDC.
Programmed output function pulled-up to +24VDC.
An external voltage via external pull-ups will determine this level, not exceed +30VDC.
Printer +24 VDC (1.5 amp maximum).
Programmed input function.
Programmed input function.
Programmed output function pulled-up to +5VDC.
Programmed output function pulled-up to +24VDC.
An external voltage via external pull-ups will determine this level, not exceed +30VDC.
Programmed output function pulled-up to +5VDC.
Programmed output function pulled-up to +24VDC.
An external voltage via external pull-ups will determine this level, not exceed +30VDC.
7