Dux Proflo 25W124P Panduan Pemilik - Halaman 4

Jelajahi secara online atau unduh pdf Panduan Pemilik untuk Pemanas Air Dux Proflo 25W124P. Dux Proflo 25W124P 20 halaman. 25l and 50l litre electric storage water heater

Dux Proflo 25W124P Panduan Pemilik
Installation Requirements
This water heater must be installed
by a licensed tradesperson, and in
accordance with
AS/NZS3500.4.2 "National
Plumbing and Drainage Code Hot
Water Supply Systems – Acceptable
Solutions".
AS/NZS3000.
Local authority regulations.
Outside Australia and New Zealand,
please refer to local plumbing and
building codes and regulations.
Notice to Victorian customers from
the Victorian Plumbing Industry
Commission – this water heater
must be installed by a licensed
person as required by the Victorian
Building Act (1993). Only a licensed
person will give you a compliance
certificate, showing that the work
complies with all the relevant
Standards. Only a licensed person
will have insurance protecting their
workmanship for 6 years. Make sure
you use a licensed person to install
this water heater and ask for your
Compliance Certificate.
2
Owner's Manual – Proflo 25/50 Litre Water Heater

Installation Details

Water Supply Pressure
This water heater is designed for direct
connection to water supply pressures
of:
25 & 50 Litre Models – 800kPa
Where the mains pressure can exceed
or fluctuate beyond the pressure
shown above, a pressure limiting
device (complying with AS1357) must
be fitted in the cold water inlet supply.
This device must be installed after
the isolating valve and set below the
pressure shown above. Note during
periods of lower demand water pressure
may increase.
Caution: This water heater delivers
hot water at temperatures exceeding
50°C. Refer to AS/NZS3500 and local
regulations regarding the need for
additional hot water delivery temperature
control.
Pool Heating
This water heater must not be used for
pool heating.
H3699
3699
Rev. F