DUYAR OPUS 25-8 180 Pengoperasian & Pemeliharaan Instalasi - Halaman 13

Jelajahi secara online atau unduh pdf Pengoperasian & Pemeliharaan Instalasi untuk Ketel uap DUYAR OPUS 25-8 180. DUYAR OPUS 25-8 180 18 halaman.

DUYAR OPUS 25-8 180 Pengoperasian & Pemeliharaan Instalasi
INSTALLATION, OPERATION, MAINTENANCE
11. FAULTS, CAUSES AND SOLUTIONS
When a situation occurs that prevents the normal operation of the pump, the pump
automatically stops and gives an error or warning code.
See Figure 7.1. Thanks to the codes written on the screen, the cause and solution of
the error can be learned. See. Table 11.1.
1) After an error / warning occurs, the pump switches to standby for 5 seconds. It starts again.
2) If the reason for the error / warning disappears after waiting for 5 seconds, the pump starts working again. If the
reason for the error / warning continues, the
pump gives an error / warning again.
3) Error / warning code is found in "P40" in the program menu of the pump.
4) All errors are stored in "P40", the last (20) errors.
If the pump fails, it cannot be restarted, service intervention is required.
CAUTION
Erroro rW arning
Code&Name
Error: E1 FOC
Error: E2
HighV oltage
Error: E4
LowV oltage
Error: E8
High Temp.
Error: E1 6
Engine Start
Error: E3 2E ngine
Rotation Speed
Error: E6 4
Engine Short
Circuit
Error: E1 28
Software Err.
AND REPAIR MANUAL
Reason
The stator andr otor do notr otate
at synchronous speedd ue to the
instantaneousc hange in load.
The supply voltagei sh igh.
The supply voltagei sl ow.C
Windingt emperature rise due to
excessive stress in thee ngine
and/or high watert emperature
Lockingo ft he rotord ue to any
foreignm attere nteringt he rotor
rotating area
The stator andr otor do notr otate
at synchronous speedd ue to the
instantaneousc hange in load.
Shortc ircuit betweenp ump and
body
Software errorC
OPUS SERIES
Solution
Checkt he suitabilityo ft he
installation water flow direction
with the arrowm arko nt he pump
body.W aitf or thep umpt o exit the
errorm ode.
Checki ft he supply voltagei s
within the specifiedr ange, wait.
heck if thes upplyv oltage is
within the specifiedr ange
It is checkedt hatt he water
temperature is notw ithin the
specifiedr ange.W aitf or thep ump
to exit the errorm ode.
Wait fort he pump to exit thee rror
mode.
Call fort he service
Call fort he service
allf or thes ervice
11