CONFIGURATION
VSC configurator – Getting started
SVS1 sensor requires a preliminary setting, that is obtained in a few steps
using the external VSC configurator.
PUSH-BUTTONS
Status
Go to next configuration step
Teach
Save the settings
Acquire a new reference image
Set
Confirm current selection
Esc
Quit without saving
Go back to previous configuration step
Arrows
Move the selection
Move/Resize Region Of Interest (ROI)
Change parameter/threshold value
Change monitor mode
i. Inspection tool selection
After connecting the VSC to the sensor, the user
has to choose the inspection tool to use. There
are 7 different control types available: brightness,
contrast, OCV, pattern match, position, width and
edge count (see also the Tool Table). Use the
ARROW buttons to choose the tool and then
press SET to confirm the selection.
ii. Camera setting
Once selected the desired inspection tool, the
user has to modify the camera parameters in
order to get a good quality image. The focus can
be adjusted directly on the sensor by turning the
focus knob on the front. All the other parameters,
instead, can be modified from the camera panel
(select Camera with the ARROW buttons and
then press SET).
In the Camera menu the user can switch the
internal and the external illuminators on or off,
increase or decrease the exposure time and the
gain and lastly invert the greyscale values.
iii. ROI definition
Each type of control is based on the definition of
a Region Of Interest (ROI). This means that the
user has to define the area in which there is the
particular to inspect. The ROI can be moved from
the Move ROI panel by using the ARROW
buttons. For the pattern match tool, there are two
different ROIs that must be set (one is the
template and the other one is the research area).
The user can switch from a ROI to another by simply pressing the SET
button. The ROI can be also resized. This can be done from the Resize ROI
panel using the ARROW buttons. Again, for pattern match tool both the ROIs
can be resized.
iv. Reference image acquisition
In order to acquire a new reference image, the user can press the TEACH
button. Please consider that after changes in ROI size/position or
camera/illuminator settings a new reference frame is acquired automatically.
Once obtained the desired configuration, it is possible to move to the next
configuration step by pressing STATUS button.
v. Parameter setting
In the second configuration step it is possible to
modify the functioning parameters of the selected
inspection tool. The user can set the desired
value by pressing UP/DOWN ARROWS to move
the slider on the right side of the display. It is
possible
to
scroll
the
parameters
using
LEFT/RIGHT ARROWS. The Status indicator on
the right side, as well as the ROI contour reveals
the result of control application by assuming red (bad result) or green (good
result) colouring.
vi. Inspection monitoring and saving
Monitor mode allows the user to control how the configured inspection works.
There are some different available monitoring options which can be recalled
using ARROW buttons. SET button, instead, activates statistics panel.
Monitor mode
To activate press
Visualises
-
STANDARD
UP ARROW
Acquired image
-
Tool used
-
Result
-
CAMERA
DOWN ARROW
Acquired image
-
FAIL
LEFT ARROW
Acquired image (the VSC
displays only failure
images)
-
Tool used
-
-
ZOOM
RIGHT ARROW
Acquired image (with
200% zoom)
-
Tool used
-
Result
-
STATISTICS
SET BUTTON
Inspection result
-
Score
-
Average score
-
Score MIN-MAX
-
Execution time
-
Average execution time
-
Measurement count
-
Failure rate (%)
If the behaviour of the system is not satisfactory, it is possible to go back to
the previous configuration steps by pressing ESC button. Once the inspection
meets the user requirements, it can be stored on the currently selected
memory slot by pressing TEACH button twice.
All the other functionalities and parameters of SVS1 are available in the MAIN
menu (from the Monitor mode press STATUS to access). Here the user can
modify some configuration options.
CONFIGURATION OPTIONS
a. Output behaviour
Three digital outputs are available on the sensor.
For each output a different behaviour can be set.
It is also possible to define the output duration and
delay.
b. Trigger mode
SVS1 can operate in continuous mode (image
acquisition, elaboration, output activation, new
image acquisition, and so on...) or with an
external trigger (on the rising edge of the trigger
signal as well as on the falling edge).
c. Bankset manager
On SVS1 there are 8 memory slots in which 8
different inspections can be stored. From the
bankset manager the user can load, store or clear
an inspection.
d. Fail inspector
The fail inspector allows the user to check the last
8 images of failure and also displays the reason
why the control failed.
e. SVS1 Version
From the panel SVS1 version it is possible to
check the firmware release installed on the
sensor.
f. Menu mode
The user interface available on the VSC can be
set in two different modes: expert mode (every
options and parameters are available) and
standard mode (less configuration options).
g. Password
It is possible to set a password in order to prevent
the access to the configuration parameters to
unauthorised personnel.
h. Reset
The reset function allows to reboot the sensor in
case of problems or malfunctioning.
TOOL TABLE
Control
Functioning
Applications
Searches for a pattern inside
Verifies logo on food
the target area
packages
Pattern Match
Verifies the quality of
Character verification
printed characters
OCV
Identifies the object position
Controls the level of
edge (edge detection)
liquids in bottles
Position
Measures the distance
Assembling control
between two points
Width
Identifies all edges along an
Counts the blisters in
axis
stack for pharmaceutical
Edge Count
Calculates the contrast in an
Verifies overprint of
image
labels
Contrast
Calculates the brightness of
Verifies the presence of
an image
cap and nozzle on phials
Brightness
MECHANICAL DIMENSIONS
DECLARATION OF CONFORMITY
We DATASENSOR S.p.A. declare under our sole responsibility that these products are conform to the
2004/108/CE, 2006/95/CE Directives and successive amendments.
WARRANTY
DATASENSOR S.p.A. warrants its products to be free from defects.
DATASENSOR S.p.A. will repair or replace, free of charge, any product found to be defective during the
warranty period of 36 months from the manufacturing date.
This warranty does not cover damage or liability deriving from the improper application of
DATASENSOR products.
DATASENSOR S.p.A. Via Lavino 265
40050 Monte S. Pietro - Bologna - Italy
Tel: +39 051 6765611 Fax: +39 051 6759324
http://www.datasensor.com
e-mail: [email protected]
DATASENSOR S.p.A. cares for the environment: 100% recycled paper.
DATASENSOR S.p.A. reserves the right to make modifications and improvements without prior
notification.
830000080 Rev.A