Datasensor TL46-W Buku Petunjuk - Halaman 2
Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Aksesori Datasensor TL46-W. Datasensor TL46-W 4 halaman. Contrast sensor
TL46-WL
Contrast sensor
INSTRUCTION MANUAL
CONTROLS
OUT LED (yellow)
The yellow LED indicates the output status.
READY LED (green)
During functioning, the green LED permanently ON
indicates a normal operating condition.
Fast blinking indicates an output overload condition.
DELAY LED (orange)
The orange DELAY LED ON indicates the timing
function activation on the digital output.
KEYLOCK LED (orange)
The orange KEYLOCK LED ON indicates the active keyboard status.
BARGRAPH
The switching threshold level is signalled on the bargraph.
PUSH-BUTTON (bianco)
The detection procedure is activated by pressing the
push-button.
(red) and
(green) PUSH-BUTTONS
The threshold adjustment procedure is activated by pressing the
push-buttons.
See the "SETTING" paragraph for the correct adjustment phase
indications.
INSTALLATION
The sensor can be positioned by means the two Ø3.5mm housing's holes
using or threaded M5 holes with 6mm max. depth.
Warning: the use of excessively long screws can damage the product.
The connector can be oriented at five different positions, rotating the block.
The position chosen is guaranteed by a mechanical blocking system.
The rotation can be carried-out even after sensor installation as the connector
block is completely self-contained inside the housing.
The operating distance is measured starting from the lens front face.
The reading direction can be changed inverting the cap and lens.
Mark detection on a reflective surface is improved adjusting the beam
direction to 5° ... 20° from surface axis.
DIMENSIONS
81.5
4.8
15.8
27.5
28
39.1
28
TECHNICAL DATA
Power supply:
10...30 Vdc (limit values)
Ripple:
2 Vpp max.
85 mA max @ 24 Vdc with bargraph ON
Current consumption
in threshold adjustment mode,
(output current excluded):
55 mA max @ 24 Vdc with bargraph OFF
in normal functioning mode
1 selectable PNP/NPN output
Output:
30 Vdc max. (short-circuit protection)
(default PNP configuration)
Output current:
100 mA max.
Output saturation voltage:
Response time:
Switching frequency:
20 kHz
Analogue output:
1 ... 3 V ± 10% (90% white); 5.5 V max.
Analogue output
2.2 kΩ
and
impedance:
(short-circuit protection)
0 / 20ms selectable
Delay
default configuration without delay
Dark/light selection:
Automatic
OUT LED (yellow) / READY LED (green)
Indicators:
DELAY LED and KEYLOCK LED (orange)
5-segment bargraph
Operating temperature:
-10 ... 55 °C
Storage temperature:
-20 ... 70 °C
Electric shock protection:
double insulation
Operating distance:
± 3 mm
Depth of field:
Minimum spot dimension:
1.5x5 mm
Blue (465 nm) / Green (520 nm) / Red (630 nm)
Emission type:
with automatic selection
Ambient light rejection:
According to EN 60947-5-2
0.5 mm amplitude, 10 ... 55 Hz frequency,
Vibrations:
for each axis (EN60068-2-6)
11 ms (30 G) 6 shock for each axis
Shock resistance:
(EN60068-2-27)
Housing material:
Aluminium
Lens material:
Glass (*)
Mechanical protection:
Connections:
M12 5-pole connector
Weight:
170 g. max.
(*)
It's available on request, PMMA plastic lens with 9mm focus.
CONNECTIONS
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: [email protected]
KEYLOCK FUNCTION (PATENT-COVERED)
The KEYLOCK function deactivates the keyboard avoiding any accidental
changes in sensor setting.
At sensor powering, the keyboard is blocked (KEYLOCK LED OFF).
The white
push-button has to be pressed for 5 sec. until the KEYLOCK
LED (orange) turns ON. The keyboard is blocked automatically if not used for
2 minutes.
The keyboard has to be unlocked to proceed with sensor setting.
15.5
DETECTION (MARK-BACKGROUND)
- Position mark in front of the sensor light spot
and press white
push-button until the
READY LED (green) turns OFF.
The sensor detects the mark alternating the
red, green and blue emissions; avoid mark
movements during this phase.
- Position the background in front of the
sensor light spot and press white
button again. The sensor detects the mark
alternating
the
red,
green
emissions. Avoid background movements
during this phase.
The
DARK/LIGHT
operating
automatically selected by the sensor.
Dark mark - light background = dark mode;
≤ 2 V
light mark - dark background = light mode.
25 μs
If the READY LED is permanently ON, the
detection is successful. If the LED blinks
slowly, the detection has failed due to
insufficient contrast. The sensor returns to the
previous setting by pressing white
Repeat the procedure from the beginning.
SWITCHING THRESHOLD SETTING
The sensor switching threshold is adjusted by pressing the
buttons (respectively increasing or decreasing the value).
At the first pressure of the
bargraph turn ON.
9 mm
Increasing or decreasing the threshold, the right or left LEDs blink with a
frequency proportional to the difference from the initial threshold value.
Increase / decrease
[1..10] pressures of
[11..20] pressures of
IP67
[1..10] pressures of
[11.20] pressures of
To save the new threshold value press white
from last change (automatic save).
DELAY SETTING
The DELAY extends to 20ms the minimum duration of the active output
allowing the slower interfacing systems to detect shorter pulses.
The active delay is signalled by the corresponding orange LED ON.
ON
OUT without DELAY
OFF
ON
OUT with DELAY
OFF
DELAY ACTIVATION
SETTING
- Press
sec. until the DELAY LED turns ON.
DELAY DEACTIVATION
- Press
sec. until the DELAY LED turns OFF.
PNP/NPN OUTPUT SETTING
The digital output can be PNP or NPN
configured.
- To change output press red
contemporaneously for 10 sec.
- The setting is signalled by the status change of the DELAY LED.
If the delay is active after pressing the push-buttons for 2 seconds, the
DELAY LED turns OFF, release the push-buttons only after LED re-
powering (10 sec.).
If the delay is deactivated after pressing the push-buttons for 2 seconds, the
DELAY LED turns ON, release the push-buttons only after LED turning off
(10sec.).
- The output setting is signalled by the KEYLOCK LED. Releasing the push-
buttons, the KEYLOCK LED blinks once if the PNP output is set, blinks
twice if the NPN output is set.
push-
Delay ON
and
blue
Delay OFF
OUTPUT OVERLOAD
mode
is
The digital output overload is signalled by the rapid blinking of the READY
LED.
REMOTE INPUT
The REMOTE signals carries-out the acquisition functions without using the
white
push-button.
push-button.
The REMOTE wire connected to +Vdc is equal to pressing the white
push-button. Whereas, if the REMOTE wire is connected to GND or not
connected it is equal to not pressing the white
or
push-
STATIC
or
push-buttons, the first three LEDs of the
DET.
ANALOGUE OUTPUT
The analogue output supplies a voltage proportional to the signal received by
the sensor. The voltage supplied is 1 ÷ 5.5V. The maximum voltage is
obtained with reflective objects; on 90% white the voltage is equal to 3V.
Bargraph
DECLARATION OF CONFORMITY
push-button or wait 30 sec.
We DATASENSOR S.p.A. declare under our sole responsibility that these products are conform to the
2004/108/CE, 2006/95/CE Directives and successive amendments.
WARRANTY
DATASENSOR S.p.A. warrants its products to be free from defects.
DATASENSOR S.p.A. will repair or replace, free of charge, any product found to be defective during the
warranty period of 36 months from the manufacturing date.
This warranty does not cover damage or liability deriving from the improper application of
DATASENSOR products.
DATASENSOR S.p.A. Via Lavino 265
40050 Monte S. Pietro - Bologna - Italy
Tel: +39 051 6765611
http://www.datasensor.com
DATASENSOR S.p.A. cares for the environment: 100% recycled paper.
DATASENSOR S.p.A. reserves the right to make modifications and improvements without
20ms
20ms
prior notification.
and
contemporaneously for 2
and
contemporaneously for 2
push-button and green
push-button
Release of push-
2 sec. pressure of
10 sec. pressure of
buttons
and
and
ACCESSORY FUNCTIONS
push-button.
V
DC
> 1s
REMOTE
GND
Mark acquisition
BKGD acquisition
EX-II-3DG IP67 T6
T6 (<85°C)
Temperature class:
Max. Power consumption:
2400 mW at 30 Vdc
Max. Internal capacitance:
450 pF
Internal inductance:
negligible
Fax: +39 051 6759324
e-mail: [email protected]
826003003 Rev.E