Type of gas used
G20 20 mbar
G30 28-30 mbar
G31 37 mbar
Burner
Auxiliary
Semi Rapid
Rapid
Triple Crown
Operation
Burner operation
• Push and turn the knob around to the spark zone of the control until the gas lights.
• Reduce the gas level to suit the cooking required.
• If the gas fails to light first time, please try again.
CAUTION:
• If there is no electric current you can light the burners with a piezo electric spark
gas ignitor.
• The burners can only be lit with safety thermocouples when the knob is on MAXIMUM.
• Do not use cooking vessels on the hob that overlap the edges of the pan supports.
TRAG10580 - 200000004 - 5 Burner Gas v3b Rv2.indd 14
Model
configuration
5 BURNERS
1AUX – 2SR – 1R – 1TC
1AUX – 2SR – 1R – 1TC
1AUX – 2SR – 1R – 1TC
Minimum Pan
Diameter (cm)
≥10
≥14
≥16
≥20
Rated thermal
flowrate
(kW)
11.15
11.10
11.10
Maximum Pan
Diameter (cm)
≤18
≤24
≤26
≤26
14
Total rated
consumption
1063 lt/h
807 g/h
793 g/h