Cooking Performance Group 351CPGSP18L Panduan Pengguna - Halaman 6

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Rentang Cooking Performance Group 351CPGSP18L. Cooking Performance Group 351CPGSP18L 11 halaman. Gas stock pot range

Cooking Performance Group 351CPGSP18L Panduan Pengguna
User Manual
351CPGDSPRN, 351CPGDSPRL,
351CPGSP18N, 351CPGSP18L
GAS CONNECTION:
Note: This installation is to be carried out by a certified technician. Issues related to installation, such as
adjustments and calibrations, are the responsibility of the installer and are not matters of warranty. Proof
of installation may be required to make a warranty claim.
1.
The serial plate is located on the side of the unit. It indicates the type of gas the unit is equipped to use.
All Equipment is set for use with the specified gas type at the factory.
2.
The equipment is design-certified for operation on either natural or propane gas; it should only be
connected to the type of gas for which it is equipped as stated on the serial plate.
3.
A 3/4" NPT inlet is located at the rear for the gas connection. The external regulator provided with the
unit must be installed. An adequate gas supply is imperative. Undersized or low pressure lines will
restrict the volume of gas required for satisfactory performance. Failure to install the supplied regulator
will void the unit warranty.
4.
Ensure the supply line is clean before connecting the line to the unit.
5.
A manual gas shut-off valve must be installed in the gas supply line ahead of the appliance and gas
pressure regulator for safety and ease in servicing.
6.
All pipe joints and connections must be tested thoroughly for gas leaks. Use only soapy water for
testing on all gases. Never use an open flame to check for gas leaks.
6
www.cookingperformancegroup.com
.