8. The appliance should be installed in a well-ventilated area, if possible under a vent
hood, in compliance with all applicable regulations in force. This will ensure that all
burnt gases produced during the combustion process are completely exhausted.
9. After installation, keep the appliance stable and level. Do not tilt or sway during
operation.
10. Before installation, remove the outer plastic films.
11. Do not use gas that not applicable to the appliance as fuel, neither does high-pressure
or medium-pressure regulating valve. (This appliance is only applicable to
low-pressure regulating valve.)
12. Before installation, a quick acting disconnecting valve should be installed upstream
the appliance where is easy to reach.
13. Making sure the applicable gas is the same as the supplied one. If not, stop using.
14. Pipeline connected to the appliance should be connected with proper metal pipe.
15. If the pressure of the gas pipeline is 10% higher or lower than the rated pressure the
appliance required, a regulator should be installed to ensure it reaches the rated
value.
16. After connecting the appliance to the gas system, check for leaks at joints and pipe
fittings; to do so, use soapy water or a specific leak detector (spray). "No Flaming!"
17. Check the gas supply pressure after installation.
18. Gas supply pressure can be measured with a liquid-filled pressure gauge (e.g. a
U-shaped pressure gauge, minimum scale division 0.1mbar) or a digital gauge.
Procedure as follows:
Remove the panel, unscrew the screw on the pressure port (Picture 2);
Place the pressure gauge;
Start up the appliance by following the instructions in the user's manual;
Check the supply pressure;
After the check, remove the pressure gauge;
Replace the sealing screw.
sealing screw
pressure port
Picture 2