Important information
o This hob is supplied to run on natural gas only and cannot
be used on any other type of gas without modification.
o Conversion for use on LPG and other gases must only be
undertaken by a qualified person. For information on the use
of other gases, please contact the Advice Line.
o The hob must be installed by a qualified person, in
accordance with the current edition of the Gas Safety
(Installation and Use) (Amendment) Regulations and the
relevant building/I.E.E. Regulations.
o Failure to install the appliance correctly could invalidate
guarantee and lead to prosecution under the regulations
quoted above.
o In the UK, GASSAFE registered installers are authorised to
undertake the installation and service work, in compliance
with the above regulations.
Ventilation requirements
o The room containing the hob should have an air supply in
accordance with the current edition of BS 5440: Part 2:
o The room must have opening windows or equivalent; some
rooms may also require a permanent vent.
o If the room has a volume between 5 and 10m³, it will require
an air vent of 50cm² (effective area). Unless it has a door
which opens directly to the outside.
o If the room has a volume of less than 5m³, it will require an
air vent of 100cm² (effective area).
o If it is installed in a room with a volume that exceeds 11m³,
then no air vent is required.
o If there are any other fuel burning appliances in the same
room the current edition of BS 5440: Part 2: should be
consulted to determine air vent requirements.
o Ensure that the room containing the hob is well ventilated,
keep natural ventilation holes or install a mechanical
ventilation device (mechanical cooker hood).
13