should match the connection type and the power rating of the ceramic
hob.
The connection cable must be secured in a strain-relief clamp.
Warning!
Remember to connect the safety circuit to the connection box terminal
marked with
.The electricity supply for the ceramic hob must have a
safety switch which
enables the power to be cut off in case of emergency. The distance
between the working contacts of the safety switch must be at least 3mm.
Before connecting the ceramic hob to the power supply it is important to
read the information on the data plate and the connection diagram.
wires for each domino hob with touch control models
Adaptive voltage range and
model
220-240 1N~
AHW-4D-
60-1
The cable connections must be in accordance with the diagram
located on the bottom of the hob.
You should use a good quality screwdriver to carefully, fully tighten
ALL of the terminal screws.
If when the hob is first switched on, only two of the zones work, you
should recheck that the terminal screws are all fully tightened. This
should be done before contacting the Customer Care Department.
IMPORTANT: The appliance must NOT be connected to the mains
supply by means of a 13A plug and socket.
This appliance must be wired into a 30 A double pole switched fused
spur outlet, having 3 mm contact separation and placed in an easily
accessible position adjacent to the appliance. It should not be located
above the appliance and no more than 1.25m away from it.
The cable can be looped if necessary, but make sure that is not kinked
or trapped when the hob is in position. Care must be taken to avoid
the cable being in contact with hot parts of the appliance.
wires
380-415 2N~
50-60Hz
H05VV-F
H05VV-F
3G2.5
7
50-60Hz
4G2.5
The wiring diagram