CookTek MagnaWave MC3002S Panduan Pemilik dan Petunjuk Pemasangan - Halaman 6

Jelajahi secara online atau unduh pdf Panduan Pemilik dan Petunjuk Pemasangan untuk Kompor CookTek MagnaWave MC3002S. CookTek MagnaWave MC3002S 6 halaman. Cooktek magnawave cooktops
Juga untuk CookTek MagnaWave MC3002S: Instalasi dan Pengoperasian Panduan Pemilik (11 halaman), Panduan Pemilik (10 halaman), Panduan Instalasi dan Pemilik (10 halaman)

In the event of a Possible Malfunction, your CookTek MagnaWave Cooktop
will display an Error Code on the LED Display. Please consult the following
table when encountering an Error Code.
Error Probable Cause
Code
1
RTD (Temperature Sensor)
Temperature Too High
2
RTD (Temperature Sensor) is not
connected or is malfunctioning
3
Current Too High
4
Electronics are Overheating
5
Input Line Voltage
(From Power Outlet) Too Low
6
Input Line Voltage
(From Power Outlet) Too High
7
Micro Communication Malfunction Turn unit off. Unplug. Without replugging unit, turn power
8
Electronics Timing Incorrect
9
RTD (Temperature Sensor)
is Shorted
Two Hob (Two Position) Cooktops
Operation of the two hob (two position) Cooktop is exactly the same as the single
position Cooktop. Each position will have its own, independently controlled, On-
Off Control Knob and its own, separately controlled, SmarTemp button. It is not
necessary to turn on both positions for the Cooktop to function.
NOTE: For Proper operation a dedicated circuit should be used for each unit
installed. Each unit should be protected with a 30 minimum circuit breaker.
8
Solution
Turn the unit off and let it cool. Unit will return to Normal
mode in a short time.
Reconnect or replace RTD
Service May be Required
Possible Mechanical damage to coil or possible foreign
object on Cooktop. Service May Be Required
Check Intake Vents. Listen for fan operation.
Service May Be Required
Turn unit off. Unplug. Without replugging unit, turn power
switch to the ON position. Turn the unit off and plug back
into the power outlet. Resume normal operation. If the
problem persists, have an electrician monitor the line voltage.
Turn unit off. Unplug. Without replugging unit, turn power
switch to the ON position. Turn the unit off and plug back
into the power outlet. Resume normal operation. If the
problem persists, have an electrician monitor the line voltage.
switch to the ON position. Turn the unit off and plug back
into the power outlet. Resume normal operation. If the
problem persists, Service May Be Required
Turn unit off. Unplug. Without replugging unit, turn power
switch to the ON position. Turn the unit off and plug back
into the power outlet. Resume normal operation. If the
problem persists, Service May Be Required
Service is required to replace RTD