5. Adjust the UV Irradiator height above the Belt. The Irradiator is mounted on a Hand Crank System that allows
the height of the curing Lamp from the conveyor Belt to be adjusted. Turn the Crank Handle located at the top
of the curing system to move the Irradiator up or down as needed.
NOTICE:
The UV light should be turned off before you look into the Curing Chamber to make an adjustment
on the Irradiator height or for any other purpose.
6. A Scale located above the Conveyor indicates the distance from the bottom of the Lamp Housing to the
conveyor Belt.
Figure 6. Hand Crank System
7. The Curing Chamber is surrounded by an enclosure but is open on top. There are panels that are screwed
onto the Chamber Housing at the entry and at the exit. These panels may be removed to allow for taller
products to pass thru the Curing Chamber. Remove only enough panels to allow your package to enter the
Curing Chamber.
8. There are two layers of Light-Blocking Curtains (Figure 10) after the entrance to the Curing Chamber and
before the exit of the Curing Chamber. The Light-Blocking Curtains are hung in slots on the top of the Curing
Chamber and can be moved within the slots if needed.