Table 1 Continued
Problem
Poor spray pattern

Spare Parts and Accessories

Options/Accessories

Item
Nozzles
Flat Spray Nozzle
Parts Kits
Model 110 (Standard-Flow Valve) Spare Parts Kit
includes seat, seat wrench, needle, Teflon packing, and Buna and Kalrez o-rings
Model 210 (High-Flow Valve) Spare Parts Kit
includes seat, seat wrench, needle, Teflon packing, and Buna and Kalrez o-rings
Stands
Front Closing Stand with Drip Cup
Dymax Model 110 & 210 Spray Valves User Guide
Possible Cause
Cured material at tip of
Needle (C) and Seat (B)
Cured material in Air Cap (A)
Incorrect atomizing air
pressure
Damaged Needle (C) and or
Seat (B)
Corrective Action
Remove air cap and clean tip
Remove air cap and clean
Adjust atomizing air pressure
Replace parts as necessary
Part Number
T15697
T15696
T17288
T15454
17