dymax 110 Panduan Pengguna - Halaman 9

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Unit Kontrol dymax 110. dymax 110 20 halaman. Spray valves

Dymax Model 110 & 210 Spray Valves User Guide
9

System Interconnect

Air
The valve is a normally-closed spray valve. It requires a 2-position, 4-way air solenoid
valve to actuate the air section. The valve should be operated with clean, dry air
between 60-100 psi. Two #10-32 threaded air ports are located on the air section of the
valve. The air port located furthest from the midsection of the valve is the air line to
close the valve. The air port located closest to the mid-section of the valve is the air line
to open the valve. Quick-connect air fittings are typically supplied with the spray valve
to fit 5/32" tubing.
Atomizing air is connected to the valve through the #10-32 threaded port located on the
fluid section (D). The atomizing air should be connected so that it turns on only when
the valve is cycled to the open position. There are two configurations that can be used
to connect the atomizing air.
The first configuration uses a single solenoid with one output. This configuration can be
seen in Figure 2. The single solenoid in this configuration is used to simultaneously open
the valve and pressurize the atomizing air regulator.
The second configuration, which can be seen in Figure 3, uses a dual solenoid to allow
independent control of the atomizing air.
Fluid
The spray valve requires a material reservoir or pressure tank to draw material from.
The material reservoir should be connected to the valve via the 3/8" OD push-to-
connect fitting already installed on the stainless steel fluid section (D) of the valve.