Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Unit Kontrol dymax 826. dymax 826 20 halaman. Disposable fluid path valve

NOTE:
The Model 826 is supplied with 0.25" (0.63 mm) O.D. polyethylene tubing. Other
tubing sizes and materials (including polyurethane, PVC, and silicone) are available for order
through Dymax. This valve is compatible with a maximum tubing size of 0.25" (0.63 cm) OD.
1.
Remove the Tube Support Assembly by loosening the three 8-32 x 3/8" Socket Head Cap
Screws (Figure 3, A).
2.
Install the Tubing over the Barb Fitting on the Nozzle Plate or insert the Tubing through
the hole provided (Figure 3, B).
3.
Reinstall the Tubing Support Assembly to the Valve Body (Figure 3, C).

Mounting

NOTE:
If the dispense valve is to be mounted in an area that limits access to the valve, it is
recommended that the set-up operation be done prior to mounting. Access to various surfaces
of the valve is necessary for periodic adjustment (see Specifications).
There are two 6-32 x .25 DP tapped holes on both sides of the dispense valve for mounting
purposes (see Figure 9).

System Interconnect

Once the dispense valve is secured to its mounting surface, connect the air line to the port
provided on the valve (Figure 4). Connect your air supply (60-90 psi [4.1- 6.3 bar]) to your valve
controller or 3-way solenoid valve (a valve controller or a 3-way solenoid valve must be used to
operate the Model 826 valve (CV of 0.01 or greater)).
Figure 4. Air-In Port
Model 826 Dispensing Valve User Guide
Air-In Port
9