Dymo LP200-Hebrew Petunjuk Penggunaan Manual - Halaman 5
Jelajahi secara online atau unduh pdf Petunjuk Penggunaan Manual untuk Pembuat label Dymo LP200-Hebrew. Dymo LP200-Hebrew 7 halaman. Electronic labelmaker
English Mode
+
LANG
Caution: Switching from Hebrew Mode to English
Mode (and vice-versa) erases the currently stored
label from memory but retains the last settings
(size, style, box, etc.). Check and adjust for
desired settings or first press RESET for standard
default settings and then switch to English Mode.
English Mode locks alphabet characters into left-
to-right Latin ONLY. It allows both CAPS (A-B-C)
and lower-case (a-b-c) characters to be keyed in
directly from the keyboard. Hebrew characters can
NOT be entered in this mode.
• To switch from Hebrew to English Mode, press the
key, release and then press the LANG key.
The cursor jumps to the left corner of the
display. As characters are keyed in,
the cursor will be to the right of the last character.
deletes one character to the LEFT of the
flashing cursor. Use of the cursor-arrows key to
position cursor is enabled.
• To return to Hebrew Mode press
, release and
then press LANG.
CURSOR
• Press Q or R to move the cursor along the text,
one character at a time.
• Press and hold to scan through the text.
• Press
+ Q or R to move the cursor to the
beginning or end of the line of text.
• When used in conjunction with certain function
keys, use Q or R to select options.
• To insert characters, position the cursor under
the character at the insertion point and then
type in the desired additional characters.
• Press H or P to move the cursor to the start of
the previous or next line of a multi-line label.
• Press
+ H or P to move the cursor to the
beginning or end of the label.
NOTE: When LANG has been set, cursor move-
ment is disabled. Exit the LANG function (by again
pressing LANG) to re-enable cursor movement.
PRINTING
First double check displayed text, size, and indica-
tors (BIG, Box, Justification, etc.) See 'PREVIEW'.
• Press the
key to print the label.
• Depress cutter lever E to release label –see p.2.
• If the display shows g g g g g g g g g , the tape
cassette installed in the machine is too narrow
for the label to be printed; change the cassette to
a wider tape or adjust the label text size.
Caution: If the print mechanism churns but no
label emerges, do NOT press PRINT again.
Remove the tape cassette and check whether it is
empty. If not, check that the ink ribbon is not torn,
and is wound taut, that the tape passes under the
cassette guideposts B (3) and that there are no
obstructions in the tape path near the roller or
print head C (1) - C (2). Carefully reinsert cassette
(wound taut), close hinged cover and print again.
+
INCREMENTAL NUMBERING
To print labels with consecutive numbering :
• Key in your starting number as the right most
digit on the label. Press
then
display will automatically move up a digit to the
next number. Press
then
to continue the
sequence.
It is also possible to include automatic incremental
numbering when printing multiple copies :
• Key in your starting number, eg. LABEL 1A .
• Next press
then
followed by H until the
desired number of copies are displayed, eg.10,
or use Q or R to move the cursor under the
number digits and key in the number required.
Press
to confirm.
Now press
then
. This will print ten labels
- LABEL 1A to LABEL 10A. While using fixed
length setting, the LP200 will stop printing when
the label exceeds the fixed length.
DELETE
• In Hebrew Mode:
Press once to delete the character to the right of
the cursor or to exit certain function key opera-
tions. Use the cursor-arrows key to position the
cursor at the left of the character to be deleted.
6
Note: If LANG is set then
each character blinking at the cursor until it has
deleted the LANG function. It will then delete the
character to the right of the cursor. Cursor move-
ment is disabled while LANG is set.
• In English Mode:
Press to delete the character to the left of the flashing
cursor or to exit certain function key operations.
+
CLEAR TEXT
Press to clear all the current text and cancel any
fixed length setting while leaving the text size and
other settings (style, box, copies, justification etc.)
unchanged. Also use to exit or clear certain func-
tion key operations.
TEXT SIZE
• The display shows the current selection of text
print size:
Height
Condensed Normal
and the
Small
Normal
BIG
• Normal and BIG heights are available only on
9mm and 12mm labels. Small (half-normal) height
is available on all labels.
• Press SIZE to select menu
Use
to select the size symbol required and
then press
to confirm the selection.
The "B" (BIG FONT) mode will produce highly visi-
ble 9mm or 12mm labels.
Note: In "B" mode all Latin characters will be print-
ed as capitals.
• To create a label in "B" mode, press SIZE for
will first delete
the size menu and then move H until "B" is
flashing. Press
The BIG indicator light switches on in the display.
• In "B" mode, you can select condensed, normal
or extended widths. The BOX/UL and Style
options are disabled. (If you have pressed Box or
Style while in BIG – press DEL to exit these
menus.)
• Conversely – if you have already set a box or
style you will not be able to select BIG without first
canceling these.
• Pressing 2-Line
switches size to small!! To reset BIG you must
first DEL the 2-Line function, then again press
SIZE, select "B" and confirm
Tip: Always monitor the sizes indicated in your
display and whether the BIG indicator light is on!
BOXED/UNDERLINED PRINTING
• If no Box/Underline option has been selected,
pressing (BOX/UL) once will display the menu
below:
Extended
Underlined -
Square Box -
Pointed Box -
Round Corners -
ZigZag Box -
Shaded Box -
• Use Q or R to move the cursor under the
desired option. Either press
option (confirmed by the
displayed), or
• When the BOX or ULINE indicator is displayed,
press
to cancel the Box/Underline option.
CAPITALS
In Hebrew Mode: Disabled.
To insert Latin Upper-Case characters use
LANG. (See 'LANGUAGE' above.)
The CAPS display indicator switches on when
LANG is set.
7
to confirm.
while in BIG automatically
.
__ =
DYMO
=
=
=
=
=
to select the
or – indicator
to exit.
or