Gage Bilt GBP7624B Manual - Halaman 4
Jelajahi secara online atau unduh pdf Manual untuk Peralatan Gage Bilt GBP7624B. Gage Bilt GBP7624B 8 halaman. Hydraulic installation tool
DESCRIPTION
The GBP7624B is a hydraulic installation tool capable of installing 1/2", 5/8" and 3/4" standard lockbolts.
It weighs 15 lbs and can be operated in any position with one hand. It has a 1.970" rivet setting stroke and a rated
pull load of 40,000 lbs.
The GBP7624B installation tool is designed to operate at pressures up to 10,000 psi on hydraulic pressure
developed by the Powerunit. Normal operating pressure is set at 10,000 psi PULL pressure and 6,000 psi RETURN
pressure, enabling the tool to pull all the fasteners listed on the selection chart without adjusting pressures.
Powerunit may be set to the pressures only needed to pull your specific fastener using 942280 pressure setting
gauge and setting pressures to amounts shown on the selection chart. The tool comes equipped with 24" hoses
and electric cord kit complete with quick disconnects.
NOSE ASSEMBLIES ARE NOT FURNISHED WITH THE TOOL AND MUST BE ORDERED SEPARATELY.
OPERATION
When the tool is connected to a powerunit, operation is controlled by a button in the handle. When the
button is depressed, a directional valve in the powerunit directs fluid to the front side of the piston
forcing it and the nose assembly collet rearward. This action causes the jaws to clamp onto the fastener
pintail and pull the sheets together. The anvil is forced forward, swaging the collar into locking grooves
of the fastener. Further force breaks the pintail off, approximately flush with the collar.
When the button is released the directional valve reverses fluid flow to the back of the piston and
pushes the nose assembly off of the swaged fastener. The pintail ejector hydraulically pushes the spent
pintail out of the nose assembly.
MAINTENANCE
The performance of any tool depends upon good maintenance practices. Following these minimal
requirements for service and care will extend the life of your tool.
*Only use a hydraulic power source equipped with relief valves and pressures set within specified
limits.
*Keep hydraulic system free of dirt. Avoid letting couplers contact a dirty floor.
*Do not use as a hammer to force fasteners into holes or otherwise abuse tool.
*Proper care by operators is necessary in maintaining full productivity and reducing downtime.
WARNING
Be sure powerunit is disconnected before cleaning, or when replacing worn or damaged components.
Severe personal injury may occur if power source is not disconnected.
4