Figure 13. Harrier IP Maintenance web page
Using the Harrier IP Serial Ports
The Harrier IP has two serial ports that may be used by the client application via the ONVIF DeviceIO
service.
Function GetSerialPorts() is used to query the list of available ports.
Function SendReceiveSerialCommand() is used to send and receive data to the port.
Refer to the ONVIF DeviceIO specification for details.
GetSerialPorts() will return two serial ports:
•
SERIAL_PORT_000: this port is connected to the block camera (for VISCA communication).
•
SERIAL_PORT_001: this port is connected to the RS-485 port on connector J7 (see figure 8).
J7 Connector: JST A10SUR10 series, example connecting cable A10SUR10SUR32W152A
PIN
1
2
3
4
5
Table 1. Pinout of PELCO/MIC (J7) connector
March 2023
HARRIER IP CAMERA INTERFACE BOARD
SIGNAL
Microphone GND
Microphone +
Microphone -
Microphone GND
Reserved
QUICK START GUIDE
Version 1.04 – March 2023
PIN
6
7
8
9
10
Page 9 of 12
SIGNAL
Reserved
GND
RS-485 -
RS-485 +
Reserved