Installation Steps (Please refer to Fig. 3, Fig. 4)
1. Ensure a ∮35mm mounting hole in the countertop.
2. do not remove or loosen the lock nut (8).
3. Ensure that the waterproof O-ring (7) is attached to the base plate
of the faucet, remove the horseshoe gasket (2) and set it aside,
and leave the rest of the parts on faucet .
4. Install faucet with the inlet threaded tube (1), water flow switch
(5) and power cable(4) through the mounting hole(∮35mm ) in
the countertop.
5. Place the horseshoe gasket (2) under the countertop (9) between
the hex lock nut (3) and countertop(9) and then tighten the hex
lock nut (3) . (Please make sure that the power cable (4) must
pass through the gap of the horseshoe gasket (2), otherwise the
power cable will be damaged and thereby cause damage to the
UVC module.)
6. Please prepare a 1/4" PE pipe of suitable length, and connect it to
the water flow switch (5) and the water supply connector.
Lock Nut(8)
Inlet Threaded Tube(1)
Horseshoe Gasket(2)
Hex Lock Nut(3)
Power Cable(4)
Black Socket(4-1)
connects to
power supply
Water Flow Switch(5)
Arrow Tip(5-2)
points upward
Green Plug(5-1)
Of Power Cable
Green Socket(4-2)
connects to
flow switch
Black
Plug(6)
connects to
water supply
( Fig. 3 )