WICK REPLACEMENT
Wick replacement should be performed on a completely cool heater after the cartridge tank has been removed and
the remainder of the kerosene in the heater has been burned off.
Use only genuine replacement wick.
Replacement wick number : Glowick 200-B, Kero-World 20401-U, Dura Heat DH-200, Pick-A-Wick-PW27.
Open the tank cover and
remove the cartridge tank.
Remove the batteries to
prevent possible burns.
Open the front grille and
remove the chimney.
Remove the wick adjusting
knob by pulling straight out.
Remove the screw on the wind
cover.
Unscrew 4 wing nuts.
Unscrew 5 screws, two from the
back and one from the right side
and two from the left side of the
cabinet.
Step 1
Remove the wind cover.
Step 4
Remove the wick adjuster
assembly.
Step 7
Step 2
Step 5
Remove the wick from the holder
by folding it toward the center
loosening it from the sharp
metal teeth on the inner surface
of the holder, and slide it out.
Step 8
10
Remove the cabinet.
By pulling it straight up.
Remove the automatic ignition
Assembly by unscrewing 2 screws.
Step 3
Step 6
Step 9