Hi-Force HEP310344 Panduan Petunjuk Pengoperasian - Halaman 18

Jelajahi secara online atau unduh pdf Panduan Petunjuk Pengoperasian untuk Pompa Air Hi-Force HEP310344. Hi-Force HEP310344 20 halaman. Electric driven pumps, general duty, medium/high flow

Hi-Force HEP310344 Panduan Petunjuk Pengoperasian
Problem
7. Cylinder/tool not
functioning correctly.
8. Cylinder/tool will not
retract.
9. Pressure gauge does
not read zero when
pump motor is stopped.
10. Gauge displays no
pressure reading.
TROUBLESHOOTING GUIDE (continued...)
Possible Cause
a. Cylinder/tool incorrectly connected
to pump.
b. Pump solenoid faulty.
c. Cylinder/tool fault.
d. Low oil level
e. Air trapped in the system
a. Valve malfunction.
b. Return flow line restricted or
blocked.
a. Pressure not relieved from system.
a. Faulty gauge.
b. Pump will not build pressure.
Operating Instruction Manual:
OM-HEP2/3-01
Solution
Check for correct system setup. Check
couplers (if fitted) for full engagement
Contact your local Hi-Force office/distributor.
See cylinder/tool's troubleshooting guide or
contact your local Hi-Force office/distributor.
Add oil as per section 5.2.
Bleed air from the system as per section 5.5
Contact your local Hi-Force office/distributor.
i. Check couplers (if fitted) for full
engagement.
ii. Run motor while retracting cylinder/tool.
Turn the adjustable pressure relief valve (8)
fully anti-clockwise to release the pressure.
Contact your local Hi-Force office/distributor
problem 3
See
18
From Serial Number:
BQ3323
above.