Dynablast BEF series Panduan Operator - Halaman 13

Jelajahi secara online atau unduh pdf Panduan Operator untuk Mesin Cuci Tekanan Dynablast BEF series. Dynablast BEF series 19 halaman. Hot water

TROUBLE
Pump motor heating
or overloading
Burner will not ignite
Unit smokes
Water temperature too low Coils liming up
TROUBLESHOOTING (CONTINUED)
POSSIBLE CAUSE
Coil scaling up
Water pump out of oil
Overload switch operated
Faulty motor
No fuel
Electrodes out of alignment
Electrode insulator failure
Replace.
Water flow switch not closing
Fuel solenoid valve not opening
Weak transformer
Plugged oil nozzle
Faulty burner oil pump .
Improper fuel
Air to burner insufficient
Fuel nozzle interior loose
Improper combustion
REMEDY
Descale coil
Fill to correct level. Check for leaks
Allow motor to cool. CAUTION – Switch may
automatically reset
Repair or replace
Fill fuel tank and check fuel filter for water and
other contaminants
Adjust.
Check for breaks, cracks, or spark trails –
Adjust, repair or replace.
Clean, repair or replace.
Clean and check transformer terminals. Replace
if necessary. Check for spark.
Replace (do not clean).
Adjust or replace.
Use No. 1 or No. 2 Fuel oil.
Air adjustment or burner – Remove soot from
coils.
Replace nozzle.
Descale.
Readjust burner.
11
BEF
SERIES