Hi-Force HPF207411HS Panduan Petunjuk Pengoperasian - Halaman 12

Jelajahi secara online atau unduh pdf Panduan Petunjuk Pengoperasian untuk Pompa Air Hi-Force HPF207411HS. Hi-Force HPF207411HS 16 halaman. Electric driven, general duty, medium flow

6.3 Pumps with Solenoid Valves

1. Set the adjustable pressure relief valve (5) if required. See section 6.1 for details.
2. Turn the motor on by pressing the green 'ON' button (1).
3. Press and hold the 'advance' button on the pendant to advance the cylinder. Release the button
once the cylinder has been advanced the desired amount. The cylinder will remain in the load
holding position when the button is released.
4. Press and hold the 'retract' button to retract the cylinder. Release the button once the cylinder has
been retracted.
NOTE: After operation of the press, it is good practice to return the cylinder piston
Inspect the pump for damage after each use.
Change the oil every 500 working hours using high quality ISO46 hydraulic oil.
Before storing ensure the cylinder piston has been fully retracted.
Have the pump serviced regularly by a Hi-Force authorised repair centre.
Operating Instruction Manual:
OM-HPF PUMP-01

7.0 Maintenance

12
From Serial Number:
BS8412