LEAK TESTING

It is of the utmost importance that a leak check is made on the 4 flare nut connections. A leak,
however small, will result in the aircon system losing capacity and endanger the compressor.
1. Use either soapy water, or a proprietary leak test solution.
Paint on each flare nut (particularly the neck) and inspect carefully for any telltale bubbles. Use a torch
to improve visibility, particularly in the A/H area.
Any leak will generally be remedied by further tightening of the flare nut. In the event of a faulty flare,
the line valves must be turned off, the A/H pumped out, and the flare remade.
2. Use an ELECTRONIC leak detector - preferred.
Test initially on low sensitivity, examining in particular the neck of each flare nut. Increase the
sensitivity until you are confident that no leak exists.
TEST TO BE CARRIED OUT BY INSTALLER PRIOR TO DELIVERY
COOLING: (ref fig.17)
NB. The unit will not run on cooling if the inside temp. is much below 18°C.
1. Turn fan speed selector to
2. Turn mode selector to
3. Adjust the thermostat counter clockwise until the condenser set is heard to
start.
Ensure that cold air is being discharged, and there are no pipe rattles etc. After
about 15 minutes of running, and providing the inside temp. is above 20°C, then
the discharge air should be 12°C or cooler than the return air.
HEATING: (ref fig.17)
NB. The unit will not heat if inside temp. is much above 28°C.
1. Turn fan speed selector to
2. Turn mode selector to
3. Adjust the thermostat to max. clockwise position.
There will be approximately 30 seconds delay before heating is apparent.
4. After about 15 mins. the discharge air will be approx. 25°C more than the
return air.

OPERATING INSTRUCTIONS

This appliance is not intended for use by young children or infirm persons without supervision. Young
children should be supervised to ensure that they do not play with this appliance.
This airconditioner may be used in cooling mode with outside temperatures from 18ºC to 48ºC, and inside
temperatures from 18ºC to 30ºC. In heating mode, the airconditioner may be used with outside and inside
temperatures up to 30ºC.
COOLING: (ref fig.17)
NB. The unit will not run on cooling if the inside temp. is much below 18°C.
1. Turn fan speed selector to
2. Turn mode selector to
3. Adjust the thermostat counter clockwise until the condenser set is heard to start.
4. Gradually over time, adjust the thermostat until comfortable conditions are maintained.
(Hi Speed Cooling)
(Cooling)
(Heating Speed)
(Heating)
(Hi Speed Cooling)
(Cooling)
7