Hi-Force TWS100N Panduan Pengoperasian - Halaman 2

Jelajahi secara online atau unduh pdf Panduan Pengoperasian untuk Alat Listrik Hi-Force TWS100N. Hi-Force TWS100N 7 halaman. Square drive hydraulic torque wrenches

FAILURE TO OBSERVE THE FOLLOWING WARNINGS COULD RESULT IN INJURY

USING THE TOOL
• Keep hands, loose clothing and long hair away from the reaction arm and working area during
operation. Do not attempt to support the tool with your hands during operation.
• This tool will exert a strong reaction force. Use proper mechanical support and correct reaction arm
positioning to control these forces. Do not position the reaction arm so that it tilts the tool off the axis
of the bolt and never use the swivel inlets as a reaction stop.
• Avoid sharp bends and kinks that will cause severe back-up pressure in hoses and lead to premature
hose failure.
• Use accessories recommended by Hi-Force.
• Use only impact sockets and accessories. Do not use hand (chrome) sockets or accessories.
• Use only sockets and accesssories that correctly fit the bolt or nut and function without tilting the
tool off the axis of the bolt.
• This tool is not designed for working in explosive atmospheres
• This tool is not insulated against electric shock. When using this tool with a pump having an electrical
power source or circuits, follow the pump instructions for proper grounding
Always wear eye protection when operating
Always wear eye protection when operating
or performing maintenance on this tool.
or performing maintenance on this tool.
The Torque Reaction Arm must be positioned
against a positive stop. Do not use the Arm as a dead
handle. Take all precautions to make certain the
operator's hand cannot be pinched between the Arm
and a solid object.
Keep body stance balanced and firm. Do not
overreach when operating this tool.
CONNECTING THE TOOL
1. Attach the twin line hose to the uni-swivel coupling of the Square Drive Torque Wrench using the spring–
loaded quick connect ends. Make certain that they are fully engaged.
2. Connect the opposite ends of the hose to the Pump in the same manner.
SETTING THE SQUARE DRIVE FOR
ROTATION
The position of the Square Drive when looking toward the Shroud will determine if the tool is set to tighten or
loosen the nut. When the Square Drive extends to the left when looking at the Shroud from the front, the tool is
set to loosen the nut. When the Square Drive extends to the right, the tool is set to tighten the nut. To change
the direction of rotation press the push button release on the drive retaining plate and pull the Square Drive out
of the Housing. Insert the Square Drive into the opposite side of the Housing and secure it by installing the push
button release retaining plate into the end of the drive.
www.hi-force.com
WARNING
Always wear ear protection
when operating this tool.
!
Do not carry the tool by the
hose.
PLACING THE TOOL IN SERVICE
ADJUSTMENTS
Page 2 of 7
TDS1288
.
Always turn off the pump and
disconnect the power before installing,
removing, or adjusting any accessory on
this tool, or before performing any
maintenance on this tool.
OFF
OFF
ON
ON
POWER
POWER
Operate at 10,000 psig (700
bar) maximum pressure.
10,000 psig
10,000 psig
(700 bar)
(681 bar)
Do not use damaged, frayed or
deteriorated hydraulic hoses and fittings.
0609