5.1 Before Each Use
Check the selected jacks load rating before use.
Ensure the jack is in good condition.
Check the external surfaces for signs of mechanical damage and/or oil leaks. If either is present,
DO NOT use the equipment until it has been serviced and returned to its proper operating condition.
Ensure the external surfaces are dirt free.
5.2 Filling with Oil
Hi-Force JCS Jacks are despatched from the factory pre-filled with oil, and ready for use. If at some stage
the jack requires to be topped up with oil, proceed as follows;
Place the jack on its back edge with the oil filler port facing upwards.
Remove the oil filler port plug (5)
Top up with high grade ISO15 hydraulic oil.
Replace the oil filler plug (5)
Wipe away any excess oil that may have spilt on the jack exterior.