Daxten VOYAGER MICRO Panduan Instalasi - Halaman 4

Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Kabel dan konektor Daxten VOYAGER MICRO. Daxten VOYAGER MICRO 8 halaman.

Orientation: Looking into the RJ45 socket pin 1 is on the left and pin 8 on the right.
Pin
Wire Colour
1
White/Orange
2
Orange/White
3
White/Green
4
Blue/White
5
White/Blue
6
Green/White
7
White/Brown
8
Brown/White
Connecting up
1.
Switch off your computer.
2.
Connect the Voyager Micro Transmitter unit to your computer's Keyboard Monitor and
Mouse ports (If using the USB transmitter then plug the USB plug into your computers USB
port).
3.
Plug in your Keyboard, Monitor and Mouse into the corresponding Keyboard, Monitor and
Mouse ports on the Voyager Micro's Receiver unit.
4.
Connect your UTP cable to the Voyager Micro's Transmitter and Receiver units.
5.
Connect the power supply unit to the Voyager Receiver unit.
6.
Power on your computer.
7.
Check that the keyboard and mouse operate correctly.
8.
Adjust the picture tuner on the Voyager Micro Receiver unit if required.
Note:
Although we would recommend connecting the Voyager Micro to a computer that is
turned off, you can connect it to a computer while it is turned on.
To do so you must connect it in the following order:
1.
Mouse connector.
2.
Keyboard connector.
3.
Video connector.
Place cables away from fluorescent lights, air conditioners, and machines that are likely to generate
electrical noise

LED indicators

The Voyager Micro Transmitter and Receiver units both have 2 LEDs above the RJ45 port.
The green LED indicates power is on. The flashing yellow LED indicates the system is connected.

Upgrading the firmware

The update software and the latest firmware are available from our website www.daxten.com, in the
product support section. There you will also find instructions on how to perform the upgrade.

Configuration options

Configure the Voyager Micro to:
Work with Unix servers
Input the monitor's DDC information
Change the hotkey from Shift to Ctrl
Enter the Voyager Micro configuration mode by pressing Shift Tab – as set out below - all 3 LEDs
illuminate. Pressing Esc exits the configuration mode and the LEDs return to normal.
Note:
Press the keys one after the other not all together.
Wire
Pair
T2
2
R2
2
T3
3
R1
1
T1
1
R3
3
T4
4
R4
4