Gaggenau AW 201 Manual Petunjuk Pengoperasian dan Perakitan - Halaman 18

Jelajahi secara online atau unduh pdf Manual Petunjuk Pengoperasian dan Perakitan untuk Kap Ventilasi Gaggenau AW 201. Gaggenau AW 201 20 halaman. Extractor hood
Juga untuk Gaggenau AW 201: Manual Petunjuk Pengoperasian dan Perakitan (13 halaman)

Gaggenau AW 201 Manual Petunjuk Pengoperasian dan Perakitan
Fig. 21
Fig. 22
Fig. 23
16
– Secure the hood on the wall with the four screws b
(Fig. 21 and 22).
For exhaust air mode proceed as follows:
– Establish the pipe connection.
– Establish the electrical connection.
– Stainless steel chimney only (AD 010-012/022):
pull the protective film off the chimney's trims.
Note: avoid damaging the sensitive metal surfaces.
– Fit the top chimney duct unit into the base. Make
sure that the fastening holes on the side are at the
top.
– Put both chimney duct units onto the hood.
– Pull the top chimney duct unit up into its final
position and secure it with 2 screws on the ceiling
holder (Fig. 23).
Note: avoid scratches when pulling the elements
apart by placing the assembly template, for
example, over the edge of the bottom chimney
paneling to protect it.
– Insert the grease filters.