Controls with microprocessor part number N7185V3 or higher contain the following new features. These controls
can be identified via the downloader as Rev. 06.
1.
This control complies with National Fire Protection Association (NFPA) requirements for temporal pulse sounding of fire notification
appliances. Fire alarms now sound as interrupted pulses consisting of three pulses and a brief pause (i.e. ring, ring, ring, pause -
ring, ring, ring, pause, etc.)
2.
Capability has been added for the control to call a pager on the secondary telephone number. This can only be used if the primary
reporting format is Ademco Contact ID. The following entries have been added to program field *49 (Split/Dual Reporting) for the
purpose of paging messages:
Primary
6 = All reports except Open/Close
7 = All reports
8 = All reports
Touch-tone codes sent to the pager are:
1911 = Alarm
1001 = Open
1002 = Close
1811 = Trouble
No restore reports are sent to the pager.
3.
Three additional user codes have been added (identified as Users 5, 6, and 7).
4.
Duress is now User 8 (no longer User code + 1).
5.
AC Loss report is now sent at a random time delay up to 1 hour. If AC is restored before the report goes out, no report will be sent.
6.
Telephone number entries can now contain * , #, and a 2-second pause.
Enter # + 11 for " * "
Enter # + 12 for "#"
Enter # + 13 for 2-sec. pause
7.
Audible Exit Warning option has been added (field *27: 0 = no; 1 = yes [default = 1]). If enabled, beeping will occur during exit time
and will change from slow to rapid beeping during last 5 seconds of exit delay.
8.
Master code is now able to change itself in normal operating mode. To change, enter:
[Master code] + [8] + [1] + [new Master code] + [new Master code] again.
9.
New Telco Hand-off feature allows the technician at the site to call the downloading facility from the control panel phone line,
initiate a site download (Master Code + # +1), and the control will immediately be on-line with the modem at the downloading
facility.
10.
If all power is lost at the control, upon power up, the armed status will be the same as it was before the power loss. Bypasses,
however, are not retained.
11.
The control checks for the physical battery connection every two minutes. If connection is lost, a visual and audible trouble is
indicated, and a communicator report will be sent (if programmed). The actual condition of the battery is still checked once every
four hours. To clear the low battery message after the low battery condition is restored, enter Test mode: [User code] + [5];
otherwise it will clear itself the next time the system checks the battery's condition.
Please Read
INFORMATION CONCERNING NEW FEATURES
–2–
Secondary (Paging number)
Alarms/ Open/Close, Troubles
Alarms, Troubles
Alarms, Open/Close, Troubles