CEG ECO-MXA 404 Panduan Petunjuk Pemasangan dan Pengoperasian - Halaman 19

Jelajahi secara online atau unduh pdf Panduan Petunjuk Pemasangan dan Pengoperasian untuk Pompa Air CEG ECO-MXA 404. CEG ECO-MXA 404 20 halaman. Multi-stage water pump with electronic press control

FAULTS, CAUSES AND SOLUTIONS

Faults
Pump does not
Interruption of the power supply,
run
short circuit or an insulation fault in
the motor coil
Pump runs,
Pump or pipes are blocked due to
but little or no
foreign matters
delivery
Lack of supply water
Primed incorrectly
Air in suction pipes
Motor overheats
Low voltage
Ambient temperature above +40 °C
or insufficient ventilation
The flow is too
Length of pipe is excessive and
little
diameter is too small
Excessive head
Pump vibrates
Incorrectly mounted/fixed
Fuse blows or
Pump jammed.
circuit breaker
Motor stator may be defective,
trips when pump
circuit leakage or insulation failure.
starts
Fuse size or circuit breaker may be
too small
Controller failure
Loss of prime or no water in tank
light
Electronic controller faulty, maybe
damaged by power surge or spike
Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may differ slightly from those illustrated and described in this publication.
Causes
Check power supply
Call an expert to check the pump unit
Check all filters/check valve for foreign matters
Ensure all taps are turned on
Repeat priming procedure (refer to page 8 for flooded suction or
page 9 for lift suction) to remove any air from the system
Check the tightness of the whole pipe up until the pump and
tighten it
Ensure power supply is not running on an extended cable
exceeding 10m. Check voltage on terminals of the motor. It should
be within ± 10 % of 230V (this should be carried out only by
qualified personnel)
Relocate pump to a cooler, better ventilated environment
Decrease pipe length and increase pipe size (diameter)
Decrease head on pump
Ensure pump is fastened to a solid surface by two mounting
screws
Get pump serviced
Check pump is primed and water supply is sufficient
Replace controller
Solutions
19