Perfusion Pressure Kit
Brass input connector hose barb size 1/4" i.d.
Max. input
Max. input
Max. input
Max. input
Max. input
pressure 100 psi!!
pressure 100 psi!!
pressure 100 psi!!
pressure 100 psi!!
5 micron bowl fi lter.
5 micron bowl fi lter.
5 micron bowl fi lter.
Press bottom button to empty.
Press bottom button to empty.
Syringes may also be placed in a water
Syringes may also be placed in a water
bath for temperature control.
bath for temperature control.
2-way stopcocks and lure-lock to 1/16" hose fi ttings are
2-way stopcocks and lure-lock to 1/16" hose fi ttings are
included for each channel to connect syringes to hose.
included for each channel to connect syringes to hose.
Hoses should continue from syringes to valves
8
(sold separately #09-04, -08 & -16)
Press regulator knob down to lock.
Pull up to unlock.
Individual air lines can be
Individual air lines can be
adjusted or turned-off.
adjusted or turned-off.
Be very careful with these
Be very careful with these
Be very careful with these
plastic hose connections.
plastic hose connections.
Multi-barrel Perfusion Pencil
#04-04-xxx
4-into-1 Pencil with tip
#04-08-xxx
8-into-1 Pencil with tip
#04-16-xxx
16-into-1 Pencil with tip
(xxx = 100, 250, or 360 µm)
Epoxy or silicon glue may be needed to
Epoxy or silicon glue may be needed to
completely seal connections between valve
tubing and the manifold tip in-ports.
Tighten removable tip for
minimum dead volume.
One of the eight lines may be connected to vacuum through a valve
programmed to suck the dead-volume clear between solutions.
Chemical Information
The tubing inside the manifold body is polyimide (nylon). The largest
The tubing inside the manifold body is polyimide (nylon). The largest
connection tubing is vinyl. The Removable tips include a medical grade
polypropylene Luer-lock fi tting with a fused silica (quartz) needle coated with
polyimide. These materials are resistant to most acids, bases and organic solvents.
To avoid dust contamination, we recommend pre-rinsing the Perfusion Pencil and
Tip with distilled water. Also, it is good practice to discard the fi rst few microliters
of solution before using the device. The Perfusion Pencil and Removable Tips are
shipped non-sterile. They can be chemically sterilized or autoclaved. However,
repeated autoclaving may weaken the adhesive bond between the Lure-lock fi tting
and the needle.
Maintenance
You can expect several years of useful lifetime for your tip if you wash it daily. Use
a syringe or vacuum to pull fi rst water, then alcohol three times each through the
tip. If the Multibarrel Perfusion Pencil is fi lled with pure salt solution, leaving it in
the syringe overnight will not usually cause the tip to block. However, if it is used
for high viscosity fl uids, fl ushing after each use is recommended.
Cutting
The Removable Tips are shipped with 1.5" (3.8 cm) length polyimide needles. They
are intended to be cut to a desired length by rolling a razor blade on them against
a hard surface. However, this may leave a small crack or barb on the tip. To get a
fl at cut, score the coating of the needle with a ceramic cleaving stone or a diamond
cutter and pull directly apart, making sure not to pull at an angle. You may notice
a larger outer tube enclosing the lower part of our smaller, 100µm needles. This is
simply for added rigidity, and can be cut if needed.
™
(sold separately)
Replacement Tips:
Part No. Description
Description
04-xxx
specify
100, 250, or 360 µm