Automated Pure Water 400 Panduan Pemasangan & Pengoperasian - Halaman 6
Jelajahi secara online atau unduh pdf Panduan Pemasangan & Pengoperasian untuk Sistem Penyaringan Air Automated Pure Water 400. Automated Pure Water 400 8 halaman. Non-electric dry chlorine pellet feeder
Chlorine Setting in PPM for Center Tube & Cap
Hole Settings in Parts Per Million
HOLE # 1 = 2 PPM
HOLE # A = 3 .5 PPM
This chart is for a 42 gallon or equivalent pressure tank.
When using an 80 gallon pressure tank, the PPM amount
will be 50% less per pump cycle. A 20 gallon pressure tank
will yield 2 times the amount.
Each number or letter will show a different hole in the cap.
Line up the 3 holes in the cap with the proper number or
letter directly under it (as per figure 1). The hole in the tube
should show in the center of the hole in the cap.
UNIT MUST BE INSTALLED AFTER THE PRESSURE TANK
U.S. PATENT NOS.
5,053,206; 4,908,190;
4,548,228; 4,407,322
PVC BALL
VALVE
CAUTION: When Draining Chlorine, Chlorine Can Bleach Clothing & May Burn Eyes & Skin.
Center Tube Must be Removed and Cleaned Each Time
Before Refilling.
(See filling information #3)
When removing center tube for cleaning, check hole set-
ting in cap.
Model 400 Non-Electric Dry Chlorine Pellet Feeder
HOLE # 2 = 8 PPM
HOLE # B = 13 PPM
400
FEEDER
HOLE # 3 = 30 PPM
HOLE # C = 40 PPM
DRAIN VALVE TO
RELIEVE PRESSURE,
AND DRAIN UNIT
After cleaning, be sure the setting is the same before
replacing cap.
Install PVC Check Valve Before Feeder if Untreated
Water is Used Before
-4-
All Holes Closed Will Deliver
60 PPM Per Pump Cycle.
CBA 3 2 1
PVC BALL
VALVE
Feeder.