HIBLOW hp-200 Manual - Halaman 4
Jelajahi secara online atau unduh pdf Manual untuk Kompresor Udara HIBLOW hp-200. HIBLOW hp-200 8 halaman. Air pumps
Juga untuk HIBLOW hp-200: Buku Petunjuk (13 halaman), Buku Petunjuk (17 halaman)
HP- 150 / 200
STEP
STEP
REPLACING THE VALVE
8
8
In case of replacing the whole diaphragm casing
block, move straight to
separate casing A and casing B, by removing 5
inner screws.
Remove the valves from casing B.
●If it is difficult to separate them, insert the tip of a
flatblade screwdriver into the clearance.
●Pull out the valves as they can be removed easily.
●Check if the valve chamber packing is broken.
STEP
STEP
9
9
Insert each new valve into the center hold of valve
seat, and secure them by pulling with radio pliers.
●When reinstalling the valves, make sure the exhaust
and intake sides are correctly fitted.
STEP
STEP
10
10
Cut away end of respective valves pulling parts
(just in front of thick parts) by scissors or nippers.
Hold the valve chamber packing between casing A
and casing B.
Then, fix them with 5 screws.
STEP
STEP
FITTING CHAMBER BLOCKS
11
11
Fit the actuating rod by aligning it with the groove
and tighten U-lock nut and flat washer by the nut
driver.
●Use new U-lock nut and washer, otherwise, U-lock nut
may work loose and cause malfunction.
4
REPLACING THE CHAMBER BLOCK
STEP 11
.
CasingB
Valve
Chamber
Packing
CasingB
Valve
Chamber
Packing
CasingA