ADEMCO VISTA-15P Series Manual Pemrograman - Halaman 13

Jelajahi secara online atau unduh pdf Manual Pemrograman untuk Sistem Keamanan ADEMCO VISTA-15P Series. ADEMCO VISTA-15P Series 17 halaman.
Juga untuk ADEMCO VISTA-15P Series: Panduan Instalasi Cepat (2 halaman)

ADEMCO VISTA-15P Series Manual Pemrograman
Type 21
Arm-Away
Type 22
Disarm
Type 23*
No Alarm Response
Type 24
Silent Burglary
Type 77
Keyswitch
Type 81
AAV Monitor Zone
Types 90-93
Installer Defined
*The system can still be armed when these zone types are in a faulted condition.
Schedules
(installer code + [#] + [6] [4]; master code can only access schedules 01-16 for VISTA-20P, 01-04 for VISTA-15P, and
events 00-07 for both controls; VISTA-15P supports up to 8 schedules, VISTA-20P supports up to 32 schedules )
No.
Event
(see list below)
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Events:
Master/Installer
00 = clear event
01 = device on/off
02 = user access
03 = latch key report
www.PDF-Zoo.com
• Arms the system in Away mode when the zone is activated.
• Pushbutton units send the user number to the central station when arming or disarming.
• User code for button must be assigned.
• Disarms the system when the zone is activated.
• User code for button must be assigned.
• Can be used on a zone when an output relay action is desired, but with no accompanying alarm (e.g.,
lobby door access).
• Usually assigned to all sensors or contacts on exterior doors and windows where bells and/or sirens are
NOT desired.
• Provides an instant alarm, with NO audible indication at any keypad or external sounder, if the zone is
faulted when the system is armed in the Away, Stay, Instant, or Maximum modes.
• A report is sent to the central station.
• Assign to zone wired to a keyswitch.
Assign to zone connected to AAV module.
Monitors 2-way voice sessions as follows:
- When the zone is faulted, all alarm sounding and dialer reporting stops, except for fire alarms,
which immediately terminate the voice session and cause a fire report to be sent.
- When the zone is restored (session ended), sounding resumes (if bell timeout has not expired)
and reports that were stopped are sent.
• These zone types can be programmed for various custom responses. See data fields *182-*185.
• Types 92 and 93 can only be programmed via the downloader.
UL: Zone types 90-93 may not be used as fire or burglar zones in fire or UL burglar alarm installations.
Device No.
Group No.
for "01" events:
for "02" events:
enter 01-18
enter 1-8
04 = forced STAY arm
05 = forced AWAY arm
06 = auto disarm
07 = display "reminder"
Partition
Start Time/
Days
for "04-06" events:
enter 1, 2, or 3
Installer Only
10 = display custom words 8-10
11 = periodic test report
– 13 –
Stop Time/
Repeat
Days
(yes/no)
Random
(yes/no)