12. Error Code

Error Code
Overcurrent protection is detected inside the controller. Check whether the three-phase wire terminal and the Hall signal
2
connector are in poor contact. After reconnecting the connector, if the state still appears, the controller or motor is
damaged.
The controller cannot start the motor correctly: check whether the three-phase wire terminal and the Hall signal connector
are in poor contact, or the load is too heavy and the system startup time exceeds 2S, such as climbing or wheel jam. If
3
the state still appears after reconnecting the terminals, the controller or motor is damaged.
4
Low battery voltage protection, under voltage protection
After the system is powered on, check whether the brake is working properly. If the brake signal is less than 0.75 volts for
5
a long period of time, the brake has failed.
6
Check whether the connection is loose between the motor cable and the controller.
Power on the system to check whether the handlebar is out of control, or the handlebar signal is less than 0.75 volts. Or
7
the customer turns the handle before the system works, and the fault can be removed after resetting.
8
Controller Error
Instrument and Controller Communication Error The yellow cable is not connected.
A/10
Controller program error or 5V error, check whether the brake signal is 5V short circuit.
D/13
Instrument and Controller Communication Error, the green cable is not connected. Or the communication protocol does
F/15
not match.
If the 5-core wire connecting the instrument and the controller fails, the specific reasons may be as follows:
(1)If the instrument cannot be turned on, the screen does not display. Possible causes: the main power cord between the controller and the battery is
not connected well, or any one of the red, black and blue wires connected between the instrument and the controller has a probl e m.
(2)If the instrument can be turned on, but it stops working after 3S. Possible cause: Any one of the green and yellow signal wires connecting the
instrument and the controller is broken circuit.