GAI-Tronics 352-102 Manual - Halaman 11
Jelajahi secara online atau unduh pdf Manual untuk Telepon GAI-Tronics 352-102. GAI-Tronics 352-102 19 halaman. Division 1 smart hazardous area telephones
Model 352-101, 352-102, 352-103, & 352-104 Div. 1 SMART Hazardous Area Telephones Page 11 of 17
Auxiliary Outputs
Each telephone includes two isolated solid state switches capable of switching a maximum of 48 V dc,
125 mA or 28 V
ac, 80 mA
RMS
connections for the auxiliary outputs. Refer to Figure 7 for the location of TB2 and TB5.
Output 1 connects to TB2 on the Main PCBA. Refer to Figure 7. This output activates at the start of an
incoming call and will extinguish when the handset is lifted from its cradle (call answered). This output
will activate with a cadence of 2 seconds ON followed by 4 seconds OFF during this time interval.
: This output is not available on models containing the Ring Relay option.
N
OTE
Output 4 connects to TB5 on the Main PCBA (adjacent to TB2). This output can be remotely controlled
via an appropriate DTMF command. This remote control output could be used to activate or control a
door latch, gate relay solenoid, alarm, etc. from the called party location.
Extreme Cold Temperature Operation
GAI-Tronics' 352 Series Division 1 SMART Telephones are equipped for operation in extremely cold
temperatures ranging to −40º C. Operation at these temperatures requires 5 V dc to be supplied to the
telephone.
To connect the power, remove the jumper from header P17 pins 3 and 4 and plug it into the adjacent J18
header. Refer to Figure 7 for connector locations.
Attach the Front Cover
After all adjustments have been completed, inspect and clean the machined flange joint surfaces of both
the cover and box. Surfaces must be smooth, free of nicks, scratches, dirt or any foreign particle build-up
that would prevent a proper seal. Surfaces must seat fully against each other to provide a proper
explosion-proof joint. Clean surfaces by wiping with a clean lint-free cloth.
Apply a light coat of Killark "LUBG" lubricant to flange surfaces and close the cover. Install and tighten
all cover bolts to 30 ft-lbs. Make certain no cover bolts are omitted. Use only those bolts supplied with
the enclosure.
: Refer to the Killark Installation, Operation, and Maintenance Data Sheet enclosed with the unit
N
OTE
for additional information.
f:\standard ioms - current release\42004 instr. manuals\42004-455b.doc
02/13
. TB2 (OUT1) and TB5 (OUT4) on the Main PCBA provide the
RMS
Pub. 42004-455B