GAI-Tronics 716-102 Panduan Pengguna - Halaman 5

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Telepon GAI-Tronics 716-102. GAI-Tronics 716-102 12 halaman. Flush-mount subset

GAI-Tronics 716-102 Panduan Pengguna
Model 716-102 and 7165-102 Flush-Mount Subsets

Installation

WARNING
Do not install this equipment in hazardous areas. Such installations may
cause a safety hazard and consequent injury or property damage.
1. Refer to Figure 5 and Figure 6 for the multi-party and single party subsets cutout details, respectively.
Drill and tap four holes in the mounting surface for No. 10-32 machine screws (included) according
to the measurements shown in to Figure 5 and Figure 6.
2. Feed the subset cable into the mounting hole.
3. Secure the subset to the mounting surface using four No. 10-32 screws and the mounting holes.
4. Plug the subset cable into the amplifier enclosure and secure the connector with the connector guard
(located on the amplifier enclosure).
Figure 5. Model 7165-102 Cutout Details
f:\standard ioms - current release\42004 instr. manuals\42004-643l2e.doc
04/13
Figure 6. Model 716-102 Cutout Details
Pub. 42004-643L2E
Page 5 of 10