DayTronic PC-HSICA Buku Petunjuk - Halaman 8

Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Perangkat Keras Jaringan DayTronic PC-HSICA. DayTronic PC-HSICA 13 halaman. High-speed serial interface card

2
S
ETUP OF
Refer to Fig. 1 and locate the three Handshake Programming Jumper Pins on the
PC-HSICA board. A "minijumper" is provided for connecting either Pin 2 to Pin 3
or Pin 1 to Pin 2. Position the jumper for the desired handshake pair:
• To tie the UART's RTS (Ready to Send) output to Pin 20 of the RS-232-C
Interface Connector, connect jumper PINS 2 and 3. THIS IS THE DEFAULT
STATE.
• To tie the UART's DTR (Data Terminal Ready) output to Pin 20 of the RS-232-
C Interface Connector, connect jumper PINS 1 and 2.
2.a.2 M
As explained above, the PC-HSICA card can be set to either HSIC or 16C650
mode in order to accommodate the driver software being used ("16C650" opera-
tion requires serial driver software specific to the 16C650 UART). The mode of
operation is set by Switch 4 of the block of HSIC Programming Switches shown
in Fig. 1. This switch should be
• OPEN for HSIC mode (the default state); or
• CLOSED for 16C650 mode
NOTE: "HSIC" mode should normally be selected for operation with standard
BASIC drivers and Windows TERMINAL, and also when the PC-HSICA is being
used in conjunction with Daytronic StartPAC, SuperPAC, and related software.
2.a.3 B
Switches 1, 2, and 3 of the block of HSIC Programming Switches shown in Fig. 1
are used to set a specific combination of
• I/O REGISTER ADDRESS—the four possible values are 3F8-3FF (COM1),
2F8-2FF (COM2), 3E8-3EF (COM3), and 2E8-2EF (COM4)—and
• INTERRUPT REQUEST NUMBER—4 or 7 for COM1; 3 or 7 for COM2; 4 or 7
for COM3; 3 or 7 for COM4
Refer to the following table to determine the switch settings that correspond to
the desired combination of these parameters for your PC-HSICA card.
REMEMBER: CONFLICT BETWEEN THE PC-HSICA CARD AND A COM PORT
AND/OR INTERRUPT PRESENTLY IN USE IS NOT ALLOWED. FOR THIS REA-
SON, THE PC-HSICA MUST BE ASSIGNED A COM PORT NUMBER THAT DOES
NOT CORRESPOND TO A PRESENTLY ENABLED COM PORT, AND AN IRQ NUM-
BER THAT IS NOT ALREADY IN USE.
2.a B
S
2-2
OARD
PC-HSICA C
O
ODE OF
PERATION
A
US
DDRESS
ETTINGS
OMMUNICATIONS
, COM P
,
ORT
AND
I
L
NTERRUPT
EVEL