FANCONNECT™ SWITCH WIRING (OPTIONAL)
INTRODUCTION
Power for the g2 controller, damper and FanConnect™
switch comes from the 24VAC supply in the furnace.
The damper draws only 35mA during the 15 seconds it
takes to open or close.
The relay in the FanConnect™ switch draws 100mA when
the controller is activating the bath fan.
All can be wired with standard 18-22awg 600V thermostat
wire.
WIRING
The switch requires an always hot
110VAC feed. (Black wire & White
neutral wire)
The Blue 110VAC switch leg (load)
powers the light circuit. It is a simple
mechanical contact within the toggle
switch. It can handle up to 450 Watts.
The Red 110VAC switch leg (load)
powers the fan. This is also a mechanical
contact within the internal relay. It can
handle up to 150 Watts. Works fine with
DC fans.
INSIDE THE FANCONNECT™ SWITCH
Inside the FanConnect™ switch is a
24VAC relay to control the 110VAC bath
fan.
Anytime the light switch is turned on,
the fan circuit is energized supplying
power to the fan.
The AirCycler® g2 controller can:
Read when the bath fan is on and
track that time.
Turn fan on for a delay time after
bathroom is used.
Turn fan on for a programmed
amount of time every hour to meet
ventilation requirements.
3191003
CONFORMS TO UL
STD. 917
Black (110VAC - Hot)
24VAC @100mA
White (Neutral)
Clock-Operated Switches (UL 917 5th Ed., Rev. October 7,
2009) & Clock-Operated Switches (CAN/CSA C22.2 No. 177-92,
Rev. October, 2000)
THERMOSTAT
Y R
W G
Y R C Wt Gt Gf Wf V
Y R C W
G
FURNACE
Class 2
conductors
FanConnect Switch
Internal Relay
7
DAMPER
AirCycler G2
FanConnect switch
FanConnect
TM
Blue (light)
Red (fan)
Any fan
up to 150w
AC DOC 8.5
REV 7/2020
Any light
up to 450w