Models 10959-903 and 10959-904 Wall-Mount Audio Messenger Interface
When interfaced to a Page/Party
modes and operates as described in the Telephone Operation section. The selected party line is hardwired
in the system and cannot be changed by the caller or the AMI configuration tool.
A user on the Page/Party
is configured using the ACT Tool. The AMI will then recognize when a station goes off-hook on the
designated party line, and will automatically dial a preprogrammed telephone number. The call is
terminated after the hang-up delay expires when the station goes on-hook.
Installation
DANGER
—Power Disconnect—The power cord is the main power disconnect for all units.
DANGER
—Disjontion de l'alimentation—Le cordon d'alimentation est la disjonction d'alimentation principale tous les appareils.
DANGER
—Para Desconectar la Alimentación—El cable de alimentación es el medio principal de desconexión del equipo.
DANGER
—Netzanschluß—Wenn man das Netzkabel aus der Steckdose zieht, dann ist die Spannungszuführung zum Gerät
vollkommen unterbrochen.
DANGER
DANGER
—To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
CAUTION
DANGER
DANGER
—Pour réduire le risque d'incendie, utiliser uniquement des conducteurs de télécommunications 26
ATTENTION
AWG ou de section supérieure.
DANGER
PRECAUCIÓN
DANGER
DANGER
—Um die Brandgefahr zu verringern, verwenden Sie bitte nur Fernmeldekabel der Stärke Nr. 26
VORSICHT
AWG oder höher.
Mounting
1. Loosen the four screws on the front cover.
2. Open the hinged front cover of the enclosure and turn it to the left.
3. Remove the cable connections between the front cover and the rear enclosure.
4. Pull the front cover of the enclosure up on the left side of the enclosure until the hinge pins pull loose
to separate the front and rear sections. Set the front half of the enclosure aside.
5. Determine the conduit or cable gland location on the rear enclosure.
Drill spots have been provided on the top and bottom for use with either a chassis punch or hole saw.
6. Cut or punch the appropriate size hole(s) in the enclosure.
™
7. Use Myers
ST-4 (1.25-inch) Scru-Tite
Reducers must be used for smaller conduit sizes to ensure proper contact with the supplied grounding
plates. Hub(s) must be connected to the conduit before being connected to the enclosure.
8. Secure the rear enclosure to the wall with screws or appropriate fasteners.
The enclosure mounting holes are 0.280-inches in diameter.
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-442D.docx
10/18
®
system, the operation of the AMI's telephone interface includes all page
®
system can also initiate a call by using the party hot dial feature. Party hot dial
DANGER
—Para aminorar la posibilidad de incendios, utilice solamente cable de telecomunicaciones de
calibre 26 (sistema AWG americano) o mayor.
®
hubs or equivalent.
Pub. 42004-442D