EDGE EVO Hi-O Networked Controller
EH400
2
2
Mounting
6
INSTALLATION GUIDE
The Hi-O Networked Controller power is derived from an external +12VDC or +24VDC power supply.
• Hi-O CANbus connections to the Hi-O Networked Controller includes the CAN V+ and CAN GND
output connections.
• Insert a voltage converter module between the CANBus and Hi-O iCLASS reader.
• The Hi-O Networked Controller is connected directly to the Ethernet switch without a PoE injector.
Unprotected
ted
Area
Hi-O iCLASS
SS
Hi-O N
Hi-O Networked
Reader
Controller
Co
Voltage
Module
Door Position
Magnetic Lock
Magne
Protected Area
12 - 24VDC
Power Supply
Ethernet Data
CANbus Power
CANbus Data
Door
Module
Switch
Local Sounder
Exit Alarm
REX Switch
Junction box not included.
©2009 - 2012 HID Global Corporation. All rights reserved.
82000-920, D.1
Remote Area
Ethernet Switch
Physical Access
Control Server
(real-time functions
not required )