Recommended ground method

For your personal safety, this air conditioner must be grounded. This air conditioner is equipped
with a power supply cord having a grounded 3 prong plug. To minimize possible shock hazard,
the cord must be plugged into a mating, grounded 3 prong outlet, grounded in accordance with
all local codes and ordinances. If a mating outlet is not available, it is the customer's responsi-
bility to have a properly grounded 3 prong outlet installed by a qualified electrical installer.
It is the customer's responsibility :
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in conformance with National
Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances.
Power Supply Cord
NOTE : Your unit's device may differ from the one shown.
This room air conditioner is equipped with a power
supply cord required by UL. This power supply
cord contains state-of-the-art electronics that sense
leakage current. If the cord is crushed, the
electronics detect leakage current and power will
be disconnected in a fraction of a second.
To test your power supply cord :
1.Plug power supply cord into a grounded 3 prong
outlet.
2.Press RESET (on some devices, a green light
will turn on).
3.Press TEST (listen for click; Reset button will trip,
and on some devices, a green light will turn off).
4.Press and release RESET (listen for click; Reset
button will latch, and on some devices, a green
light will turn on). The power supply cord is
ready for operation.
NOTES :
The Reset button must be pushed in for proper
operation.
The power supply cord must be replaced if it fails to trip when the test button is pressed or
fails to reset.
Do not use the power supply cord as an off/on switch. The power supply cord is designed as
a protective device.
A damaged power supply cord must be replaced with a new power supply cord obtained from
the product manufacturer and must not be repaired.
The power supply cord contains no user serviceable parts. Opening the tamper-resistant case
voids all warranty and performance claims.
A. Reset button
B. Test button
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can
result in death, fire, or electrical shock.
5