DynaLock 3000LC Series Petunjuk Instalasi - Halaman 3

Jelajahi secara online atau unduh pdf Petunjuk Instalasi untuk Dengan kunci DynaLock 3000LC Series. DynaLock 3000LC Series 4 halaman. Electromagnetic lock
Juga untuk DynaLock 3000LC Series: Manual (6 halaman), Panduan Petunjuk Instalasi (12 halaman)

DynaLock 3000LC Series Petunjuk Instalasi
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
EXPLODED PARTS VIEW
10
12
5
11
ARMATURE
ASSEMBLY
(TYPICAL)
M2011MOUNTING
MODEL 2011 & 3000LC SINGLE
OUTSWING ELECTROMAGNETIC LOCK
INSTALLATION INSTRUCTIONS
1
2
3
4
15
8
14
7
9
6
LEGEND ON NEXT PAGE
Page 6
705 Emmett Street Bristol, CT 06010
1-877-DynaLock www.dynalock.com
Inspect the door frame and determine if an angle bracket or filler plate will be required for installation. The lock will
require a 2" wide header stop for a suitable mounting surface.
2-3/16"
NORMAL
MOUNTING
1. Fold the template on the dotted line to form a 90 degree
angle. Scoring the template with a straight edge and a
screwdriver will make it fold easier.
2. With the door closed and in the latched position, from the
push side, place the template against the header and door on
the frame, and tape in place.
13
3. Transfer all hole locations to both the door and header
with a center punch, then remove the template from the door.
4. Referring to the template drill two 1/8" diameter lock mounting holes (or tap for 10-24) and one 9/16" diameter
wiring hole in the top of the frame, at all transferred locations. Remaining mounting holes will be drilled after the
lock is first mounted and adjusted (page 6).
5. Drill the remaining transferred holes in the face of the door to accept the armature following the instructions on
page 4 for your specific door type.
12/10
M2011MOUNTING
MODEL 2011 & 3000LC SINGLE
OUTSWING ELECTROMAGNETIC LOCK
INSTALLATION INSTRUCTIONS
MOUNTING CONSIDERATIONS
2-3/16"
FILLER PLATE
SPACER PLATE
REQUIRED*
REQUIRED*
*See Price Book or Call DynaLock Corp.
USING THE TEMPLATE
Page 3
ANGLE BRACKET
REQUIRED*
Emergency Tech Support is available Monday - Friday, 5:00PM-8:00PM (EST)
By Calling: Mike @ (860) 637-2394 or Glen @ (860) 637-2599
1/8" DIA. DRILL
PLACE AGAINST HEADER
9/16" DIA. WIRING HOLE
FOLD ON DOTTED LINE
OPPOSITE HINGES FOR
PLACE AGAINST JAMB
PLACE AGAINST JAMB
OPPOSITE HINGES FOR
L.H.R. DOOR INSTALLATION
R.H.R. DOOR INSTALLATION
2011/3000LC SERIES
1/8" DIA. ARMATURE HOUSING MOUNTING
ELECTROMAGNETIC
SCREW HOLES 1" DEEP (4 REQ'D.)
LOCK
DynaLock
11/32" DIA. DRILL FOR THRU BOLT MOUNTING OR
5/16"-18 TAP FOR MOUNTING ON REINFORCED DOOR
(SEE INSTRUCTIONS)
CARDBOARD
TEMPLATE
12/10