AutomationDirect IronHorse GSDA-AI-A8 Panduan Pengguna - Halaman 9

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Unit Kontrol AutomationDirect IronHorse GSDA-AI-A8. AutomationDirect IronHorse GSDA-AI-A8 12 halaman. Analog module

AutomationDirect IronHorse GSDA-AI-A8 Panduan Pengguna

GSDA-AI-A8 Software Parameters

NOTE: Add the "Slot" Number (100, 200, 500) X 10 to the Item number below to determine the actual
Item Number in the GSD8 Drive's Item-Numbering scheme. For example, to set Item 41 of an GSDA-
AI-A8 in Slot 200, you would select Item 2041 (200 X 10 + 41).
Parameter
0
Select parameter 0 to return to Run mode
1
Model Number
2
Software Version
3
Hardware Version
4
Device Type
5
Minimum Supported Framework Version
6
Maximum Supported Protocol Version
7
Serial Number (Major)
8
Serial Number (Minor)
GSDA-AI-A8's Target Speed to Drive @ 4mA
20
Input Current
GSDA-AI-A8's Target Speed to Drive @ 20mA
21
Input Current
22
4mA Input Trim
23
20mA Input Trim
Actual (S1 tach) Speed from Drive needed to
40
Produce 4mA Output Current from GSDA-AI-A8
Actual (S1 tach) Speed from Drive needed to
41
Produce 20mA Output Current from GSDA-AI-A8
42
4mA Output Trim
43
20mA Output Trim
70
Input Current to GSDA-AI-A8
71
Target Speed to Drive from GSDA-AI-A8
72
Output Current to Drive from GSDA-AI-A8
GSDA-AI-A8 Condition Flags (not yet
73
implemented)
74
GSDA-AI-A8 Auto/Manual Switch State

GSDA-AI-A8 Software Parameter Descriptions

Parameter
Parameter Name
1
Model Number
2
Software Version
3
Hardware Version
4
Device Type
IronHorse GSDA-AI-A8 User Manual – 1st Edition – 06/13/2019
Description
Read-Only Parameters
4-20 mA Input Scaling Parameters
4-20 mA Output Scaling Parameters
Read-Only Real-time Process Variables
Read-Only Identification Parameters
This number represents the base model number for the product� The model
code for the GSDA-AI-A8 card is 420� In this manual, where appropriate, the
"Drive" in which this GSDA-AI-A8 card is installed is called the GSD8 Drive�
The software version is a code which identifies the software "build number" of
the unit�
The hardware version is a code which identifies which hardware was used to
build the unit�
This value is primarily used to determine whether the particular card has
on-board non- volatile storage for its parameter settings� The GSDA-AI-A8 is a
"Type 1" card (value = 100), which does not have its own non-volatile storage�
It depends on the GSD8 Drive to store its parameter settings� This means
that if a GSDA-AI-A8 must be replaced in a GSD8 Drive, the "new" GSDA-AI-A8
does not need to be configured� It will simply "inherit" the "old" GSDA-AI-A8's
parameter settings, provided it is placed in the same slot�
Value Range
n/a
420 = GSDA-AI-A8
1 – 9999
1 – 9999
100 = Type 1 Communications Card
1 – 9999
1 – 9999
0-9999
0-9999
0 – 9999 (Limited by Drive's Display
Minimum Setting)
0 – 9999 (Limited by Drive's Display
Maximum Setting)
-600 – +600
1
-600 – +600
1
0 – 9999
0 – 9999
-600 – +6001
-600 – +6001
0 – 4095
0 – 9999
0 – 4095
0 = No Active "Flags"
1 – 9999 = Flags Activated
0 = Manual Mode
1 = Auto Mode
Description
Units
Default
n/a
420
100
n/a
n/a
(Eng�
0
units)
(Eng�
2400
units)
0
0
(Eng�
0
units)
(Eng�
2400
units)
0
0
ADC
n/a
Steps
(Eng�
n/a
units)
(Eng�
n/a
units)
BCD
0
0
Page 9