Dynamic DX2-PMA90LG Adendum Panduan Instalasi - Halaman 7
Jelajahi secara online atau unduh pdf Adendum Panduan Instalasi untuk Unit Kontrol Dynamic DX2-PMA90LG. Dynamic DX2-PMA90LG 20 halaman. The ultimate powerchair control solution
2.2 Mechanical Specifications
M5
Parameter
Installed depth including connectors
Mounting torque (M5 bolts)
Weight
Operating Temperature Range
Storage Temperature Range
Operating Humidity Range
Battery Connector Cycles
Motor Connector Cycles
Material
Protection rating
: Issue 2.03 - May 2012
GBK65148
Warning:
To achieve the specified IPx4 rating, do not mount the DX2 Power Module
with the connectors facing upward. In addition, add a water shielding cover
if necessary to protect the Power Module from water entry as appropriate to
the environment that the chair will be used in
All dimensions ± 0.5 mm.
Min
Nom
Max
140
5.51
2
4.5
1040
-25
50
(-13)
(122)
-40
65
(-40)
(149)
0
90
10
100
pressure die cast aluminium alloy
IPx4
.
Units
mm
inch
Nm
g
°C
(°F)
°C
(°F)
%RH
cycles
cycles
7