Hidro-Water XENA 10.1 Panduan Pengguna & Pemasang - Halaman 4
Jelajahi secara online atau unduh pdf Panduan Pengguna & Pemasang untuk Sistem Penyaringan Air Hidro-Water XENA 10.1. Hidro-Water XENA 10.1 13 halaman.
4.- INSTALLATION
The system can be installed anywhere in the residence where there is a water input, a drain
for water waste, a 220 – 240 V socket within a metre and sufficient space to be located. The most
common place is under the kitchen sink. The installation should be carried out by qualified personnel.
4.1.- Faucet installation (Figure-3)
A
B
a. Choose the location on the counter where you
want to install the faucet.
b. Use a drill with a 12mm bit to make a necessary
C
sized hole to put the faucet.
c. Fit the tap in the hole as indicated in the
image using a spanner (our reference: OI-
D
0207-128 not supplied with system) to adjust
it tightening the nut.
E
F
4.2.- Feed Adapter installation (Figure-8 & Figure-9)
1
a.
The water supply input consists of two parts; a brass ball valve (Figure-9) and an adaptor
(Figure-8). The brass ball valve must be screwed to the adaptor using enough Teflon on its
thread, as shown in the image below.
b. Turn off the water supply at the point where you are installing the osmosis system.
c. The water supply input is designed to be used with hoses with a ⅜" connection. Insert the
water feed adapter with the brass ball valve between the cold water supply and the hose.
(Never install a hot water connection as the osmosis system will be damaged). Make sure that
the brass ball valve is closed.
Adapter
Connect to water
supply
Place teflon
MA-EN-OSMOSIS XENA10.1-RO-0220-22-FLC-21-V01.0
6
2
3
4
5
6
7
Margarita Faucet
Cover plate
Upper O-ring
Lower O-ring
Plastic Fixing
Washer
Nut
3/8" Faucet Adapter
3/8" Security clip
2
3
4
5
6
7
Connect 3/8" hose
Brass ball valve
Connecto to the osmosis
system with 3/8" tube
4.3.- Drain clamp installation (Figure-7)
a. The drain clamp is designed to adjust the drainpipe
sealing to 1 ½".
b. The drain clamp should always be installed above the
8
U-bend (before it) and in the case of a horizontal drainpipe,
install it above (at the top). Do not install it near to the waste
A
outlet as it could clog the drainpipe.
c. Drill a 6mm hole in the drainpipe.
B
d. Align the clamp hole with the hole in the drainpipe and
carefully tighten the screws on the clamp until it is fixed into
place. Do not over tighten.
C
4.4.- Cartridge installation
D
a. The cartridges come pre-installed in the system's filters,
E
but you must remove the plastic packaging they're in
before using the system. To do so, you must remove the
filter housing at the bottom of the system using the wrench
F
supplied with the system (Figure 4) as shown in the figure;
8
remove the cartridges and remove the packaging.
b. Place the new cartridges making sure they are fitted in the correct order as shown in the figure
below to assure a good operation of the osmosis system.
C
B
A
A
B
MA-EN-OSMOSIS XENA10.1-RO-0220-22-FLC-21-V01.0
C
7