Hidro-Water KOBE WS1CI UF Panduan Pengguna & Pemasang - Halaman 10

Jelajahi secara online atau unduh pdf Panduan Pengguna & Pemasang untuk Dispenser Air Hidro-Water KOBE WS1CI UF. Hidro-Water KOBE WS1CI UF 19 halaman. Water conditioning system

Once all of the air has been removed, completely open
the softener's inlet valve to rinse the resins (during the first
rinse, the water may appear yellowish) wait until the water
runs clean, without bubbles and is transparent.
SOFTENER
SOFTENER
Plug in the transformer. Since the last step, the valve in in
TIME
REMAINNING
the BACKWASH cycle.
REGEN
Simulta n e o usly pres s t he
MIN
3 seconds to cancel the regeneration.
BACKWASH
If it has been disconnected for a long period of time, it might be necessary to repeat
the 'set the time' protocol

8.2.- Fill verification

Press
BRINE UP cycle
Press & release
When it's fully positioned, press and release
into the RINSE cycle
SOFTENER
SOFTENER
When it's fully positioned, press and release
TIME
REMAINNING
into the FILL cycle
REGEN
Let the FILL cycle fully finish. (The system will go back to
MIN
the service status on its own).
FILL
Depending on your Kobe model, your softener should have filled in the brine tank as follows:
Softener
KOBE 14
KOBE 22
KOBE 35
18
MA-EN-DESCALCIFICADOR KOBE (USR) UF-3004-XX JD18V01
and
buttons for
NEXT
REGEN
for 5 seconds. The softener will go into the
REGEN
To go into BACKWASH
REGEN
REGEN
REGEN
Water (FILL)
5 L
7 L
11L

8.3.- Suction verification

8.3.1 Suction

TIME
REGEN
Check that it's pulling water from the tank, until reaching the end of the nozzle (suction filter).
This step is extremely important to assure that the system works correctly
In the event of not pulling water or taking in air in the suction line:
Cancel the regeneration by simultaneously pressing the
Close the valves.
Check, take apart and press tightly all of the suction line's components.
Open the valves and check to see if it's solved.

8.3.2 Filling

to go
TIME
REGEN
to go
Once it's totally positioned in the cycle, press and hold the
Repeat this step until reaching the FILL cycle.
Once positioned in the FILL cycle, let it finish in its own. The system will automatically go back
the service status.

8.4.- Start up

SOFTENER
Press
REGEN
for 5 seconds. The softener will
REMAINNING
go into the BRINE UP cycle.
Check that the valve is pulling water from
MIN
the deposit evenly without taking air in
BRINE
(bubbles).
REGEN
A filling cycle must be carried out to have saturated
REMAINNING
brine prepared for the next regeneration.
Press the
button for 5 seconds to start an
MIN
REGEN
immediate regeneration.
FILL
button to skip onto the next cycle.
REGEN
Put the bypass valves in the service position.
From that moment, we'll have softened water in
our system.
SOFTENER
MA-EN-DESCALCIFICADOR KOBE (USR) UF-3004-XX JD18V01
+
buttons.
NEXT
19