ADEMCO LYNX-AVM Panduan Instalasi dan Pengaturan

Jelajahi secara online atau unduh pdf Panduan Instalasi dan Pengaturan untuk Unit Kontrol ADEMCO LYNX-AVM. ADEMCO LYNX-AVM 4 halaman. Audio verification module

ADEMCO LYNX-AVM Panduan Instalasi dan Pengaturan
®
Introduction
The LYNX-AVM is an audio verification module that allows
2-way communication between a Central Station Operator
and a person at the protected premises.
The LYNX-AVM is compatible with the following control
panel families: LYNX /LYNXR, VISTA-10P, VISTA-15P,
VISTA-20P, and VISTA-20PS.
This document provides:
UL
How Alarm Verification Works
The following table shows the stages of audio alarm verification.
1
Alarm occurs
2
Listen-In To
Follow
3
Audio
Verification
4
End Call
Wiring the LYNX-AVM
The LYNX-AVM can be wired to either a LYNX/LYNXR Security Control Panel or a VISTA-10P, VISTA-
15P, VISTA-20P, or VISTA-20PS Control Panel. The following paragraphs provide the wiring
instructions for each.
Wiring to a LYNX/LYNXR Security Control Panel
Refer to the diagram on the next page when making wiring connections from a LYNX-AVM to a
LYNX/LYNXR Security Control Panel.
1.
2.
3.
Installation and Setup Guide
an overview of audio alarm verification (AAV)
instructions for wiring to the LYNX-AVM and installing
the battery
programming information.
This device is not applicable for UL Listed installations.
Stage
The Control Panel...
seizes the phone line and
reports the alarm to the
Central Station.
ends the report with a "listen-
in to follow" message
(Contact ID event code
E606).
LYNX-AVM, then gives up
phone line. Sirens and
keypad sounds are shut off.
Control stands by for next
alarm.
stands by for next alarm.
Remove the face plate of the LYNX-AVM by removing the retaining screw and separating the plate
from the back box.
Connect the flying leads of the RJ-12 cable (supplied) to the LYNX/LYNXR Security Control Panel
terminals as shown below.
Route the cable through the hole in the base of the LYNX-AVM.
Audio Verification Module
The LYNX-AVM...
stands by.
stands by.
receives "kissoff," activates,
and holds the phone line
without breaking the
connection to the Central
Station.
hangs up the phone line.
K3703V4 3/03
LYNX-AVM
®
03000-001-V0
The Central Station...
Digital Receiver processes the
alarm report.
Digital Receiver holds the phone
line connection for one minute.
operator can pick up the phone
to speak to person at protected
premises, who in turn can reply
using the built-in microphone in
the LYNX-AVM. See
Activation/Operator Commands
section.
operator ends the conversation
and proceeds according to
central station procedures.